Summary of Contents for Glunz & Jensen InterPlater MD 85 Thermal
Page 1
Instruction Preventive Maintenance Kit Major Plate Processors MD Thermal IMPORTANT This instruction and procedure described is for authorized service technicians only. April 28th, 2022 Edition B, Part No 10107159 English (en-us) Original version...
Page 2
Introduction Introduction Kit number This instruction is valid for kit number 10107160. Estimated timing for the upgrade: 180 minutes. Products covered The above mentioned preventive maintenance kits are for the following processors: Product Serial numbers Plate Processors MD 85 Thermal 10097800 Plate Processors MD 125 Thermal 10103140 CAUTION: Verify that the serial number specified on the processor name plate located on the rear...
Page 3
Introduction Maintenance intervals NOTE: Carry out this maintenance procedure either after below specified processing hours, or after specified years after installation of the processor, whatever comes first. Kit no. Processing hours Years after installation Maintenance 125/150/165 1500 or MINOR 10060926 10060930 3000 or MEDIUM...
Page 4
Procedure Procedure Drive motor • Open the top covers, remove the fenders. • Disconnect the cable from the drive motor. • Dismount the screws from house bearing (a). • Dismount the screws (b) that hold drive motor bracket to the tank. •...
Page 5
Procedure Drive shaft • Disconnect the drive shaft ground cable. • Dismount the screws (i) and nuts (j) that hold the drive shaft bearings to the tank as shown and then remove the complete drive shaft. • Dismount r-clips from the axial bearings (2) and from the worm gears (k). •...
Need help?
Do you have a question about the InterPlater MD 85 Thermal and is the answer not in the manual?
Questions and answers