Download Print this page

Sharp AR-200M Manual page 103

Advertisement

Main
Sub
Contents
code
code
46
20
SPF exposure correction
29
Image contrast adjustment
(600dpi)
30
AE limit setting
31
Image sharpness adjustment
Used to adjust the exposure correction amount in the SPF mode (for the OC mode).
(Operating procedure)
When this simulation is executed, the current set value is displayed.
Enter the adjustment value with the 10-key and press the [START] key.
The entered set value is stored and a copy is made.
When the [INTERRUPT] key is pressed, the entered value is saved and the machine goes into the
sub code entry standby mode. When the [CA] key is pressed, the entered value is saved and the
simulation is terminated. [1] ~ [99] (Center [50])
*
The greater the set value is, the darker the density is. The smaller the set value is, the lighter the
density is.
*
The exposure mode is TEXT fixed. The LED does not change, either.
The exposure level can not be adjusted.
Used to adjust the contrast for each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading are performed, and the current set value is
displayed in two digits. (Default: 50)
The density LED is not lighted.
Change the set value and press the [START] key, and a copy is made according to the set value.
The greater the set value is, the higher the contrast is.
The smaller the set value is, the lower the contrast is.
In this case, only a copy at Exp. 3 is made.
However, the contrasts at Exp.1 and Exp. 5 are also changed accordingly.
To select a desired copy mode, press the [Copy mode select] key.
The selected copy mode set value is displayed on the copy quantity display.
(Adjustment range: 1 ~ 99)
Display lamp
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
TEXT mode lamp & PHOTO mode lamp
AE mode lamp & PHOTO mode lamp
Used to set the AE and the limit value at AE (toner save).The set range is 0 ~ 31. The default is 0.
Change the setting and press the [START] key, and it will be written into the EEPROM and the
machine will go into the sub code input standby mode. When the [Copy mode select] key is pressed,
the machine goes back to the gamma table setting mode.
Display lamp
AE mode lamp
AE mode lamp $ PHOTO mode lamp
<Remark>
When SIM26-60 (Destination setting) and SIM46-19 (Auto exposure mode) are changed, this set
content of this simulation is also changed to the default.
Used to adjust clear/shading of image for each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading are performed, and the current set value is
displayed in two digits. (Default: 1)
Change the set value and press the [START] key, and a copy is made according to the set value.
Set value
0
1
2
Use the [Copy mode select] key to select each copy mode. The code number of the selected copy
mode is displayed on the copy quantity display.
Display lamp
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
TEXT mode lamp & PHOTO mode lamp
AE mode lamp & PHOTO mode lamp
AR-M205 SIMULATIONS 7-15
Details of operation
AE mode (600dpi)
TEXT mode (600dpi)
PHOTO mode
TS mode (TEXT) (600dpi)
TS mode (AE) (600dpi)
Limit value for AE
Limit value for AE (Toner save)
Image quality
Shading
Standard
Clear
Copy mode
Setting mode
*Default
Copy mode
AE mode
TEXT mode
PHOTO mode
TS mode (TEXT)
TS mode (AE)

Advertisement

loading

This manual is also suitable for:

Ar-160mAr-m205Ar-m160Ar-5220