important Heater details:
•
The maximum temperature for which the hot tub can be set is
104°F (40°C) and the minimum is 80°F (27°C).
•
For Cameo and Optima hot tubs powered with a 40 amp service,
turn off jets pump #1 and jets pump #2 to operate heater.
•
Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
•
The heater operates until the water reaches the programmed "set
temperature", then turns off. The heater will reactivate after the
water cools to approximately 1° below the "set temperature."
8. Place Cover On Hot Tub
•
Keeping the insulating cover in place
use will reduce the time required for heating, thereby minimizing
operating costs.
•
The time required for initial heat-up will vary depending on the
starting water temperature.
dANGer:
!
Check water temperature carefully before entering hot tub!
Excessive water temperature can cause burns, welts and
body temperature to rise, hyperthermia (over-heating).
decontamination Procedure (Steps 9-15)
Steps 9-15 below are only required when sanitizer levels are unstable
after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer
levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine after
performing steps 1-6 above.
9. Add 2.5 ounces of sodium dichlor for every 100 gallons of water.
Refer to the table (page 20) for approximate water fill capacity by
model.
CAUTiON: riSk OF PerSONAL iNjUrY Or SPA dAMAGe!
!
Never add chlorine tablets (trichlor) or acid to your hot tub
for any reason! These chemical may damage components
within your hot tub, burn or irritate your skin, create a rash,
and void the manufacturer warranty for your spa.
riSk OF PerSONAL iNjUrY.
anytime the hot tub is not in
880 SERIES
Page 19