important Heater details:
The maximum temperature for which the hot tub can be set is
104°F (40°C) and the minimum is 80°F (27°C).
For Cameo and Optima hot tubs powered with a 40 amp service,
turn off jets pump #1 and jets pump #2 to operate heater.
Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
The heater operates until the water reaches the programmed "set
temperature", then turns off. The heater will reactivate after the
water cools to approximately 1° below the "set temperature."
8. Place Cover On Hot Tub
Keeping the insulating cover in place
use will reduce the time required for heating, thereby minimizing
operating costs.
The time required for initial heat-up will vary depending on the
starting water temperature.
dANGer:
!
Check water temperature carefully before entering hot tub!
Excessive water temperature can cause burns, welts and
body temperature to rise, hyperthermia (over-heating).
decontamination Procedure (Steps 9-15)
Steps 9-15 below are only required when sanitizer levels are unstable
after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer
levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine after
performing steps 1-6 above.
9. Add 2.5 ounces of sodium dichlor for every 100 gallons of water.
Refer to the table (page 20) for approximate water fill capacity by
model.
CAUTiON: riSk OF PerSONAL iNjUrY Or SPA dAMAGe!
!
Never add chlorine tablets (trichlor) or acid to your hot tub
for any reason! These chemical may damage components
within your hot tub, burn or irritate your skin, create a rash,
and void the manufacturer warranty for your spa.
riSk OF PerSONAL iNjUrY.
anytime the hot tub is not in
880 SERIES