Section 5: Velociti® And Swift™ Slc Device Installation; List Of Velociti Slc Devices; Swift™ Wireless Slc Devices; Maximum Number Of Devices - Honeywell Gamewell-FCI GWF-7075 Installation And Operation Manual

Addressable fire alarm control panel
Table of Contents

Advertisement

Section 5: Velociti
CAUTION:
To avoid the risk of electrical shock and damage to the unit, turn off the power at the control panel, when you install or service
!
the panel.

5.1 List of Velociti SLC Devices

The following Velociti mode SLC devices can be used with the control panel. See the device installation instructions for more informa-
tion (packaged with the device). For additional information on the compatible devices, refer to the Compatibility Addendum for
Gamewell-FCI Manuals, P/N:9000-0427-L8.
Part Number
Model Name/Description
ASD-PL2F
Photoelectric smoke detector
ASD-PTL2F
Photoelectric smoke detector
with thermal (135°F
ASD-PL2FR
Photoelectric replacement
smoke detector with remote test
capability in DNR
MCS-Acclimate2F Multi criteria photoelectric
smoke detector with thermal
(135°F)
ABD-2F
Reflected beam smoke detector
without test feature
ABD-RT2F
Reflected beam smoke detector
with test feature
DNR/DNRW
Duct smoke detector housing.
Non-relay (ASD-PL2FR or
ASD-PL2Fsold separate)
ATD-L2F
Fixed temperature thermal
detector (135°F)
ATD-RL2F
Rate-of-rise thermal detector
with 135° fixed temperature
ATD-HL2F
Fixed high temperature thermal
detector (190°F)
MS-7ASF
Addressable single action pull
station
MS-7AF
Addressable dual action pull
station
M500X
Fault isolator module
AMM-4F
Monitor module
AMM-2F
Mini monitor module
AMM-2IF
Dual input monitor module
MMI-10F
10 input monitor module
AOM-2RF
Addressable relay module
MMO-6RF
Six relay control module
AMM-2RIF
Dual relay/monitor module
MCS-COF3
Photo/CO Thermal/IR, Multi-
Criteria, CO
5.2 SWIFT™ Wireless SLC Devices
The VW-GATE acts as a bridge between a group of wireless fire devices and a SLC loop on the GWF-7075. It is powered by the SLC
loop or by a regulated, external 24VDC UL-listed power supply. Available wireless devices include a photo detector, a photo/heat detec-
tor, a fixed-temperature heat detector, a rate-of-rise detector, and a monitor module. For updated details about wireless devices, system
setup and operation see the SWIFT

5.3 Maximum Number of Devices

The GWF-7075 supports Velociti and SWIFT devices on one GWF-7075 system. The maximum number of devices per system varies
depending on device protocol Device support is as follows:
Velociti mode–An GWF-7075 system can support a total of 75 Velociti detectors and 75 Velociti modules. For a maximum of 150
points.
SWIFT Wireless Devices–A SWIFT Gateway system supports up to 50 devices: 1 SWIFT Gateway and up to 49 (in any
combination) wireless detectors and monitor modules. Multiple Gateways can be used. See the SWIFT manual
P/N LS10036-000GF-E for more information.
34
®
and SWIFT
Install Sheet PN
I56-3560-00
I56-3568-00
I56-3560-00
I56-2741-00
I56-2741-111
I56-3051-00
I56-3557-00
I56-3564-00
I56-3555-00
I56-1382-00
I56-4071-00
I56-3554-00
I56-2750-00
I56-2743-00
I56-3551-00
I56-2739-00
I56-3728-00
I56-6604-00
Table 5.1 Velociti Mode Devices
®
Smart Wireless Integrated Fire Technology Manual # P/N LS10036-000GF-E.
GWF-7075 Addressable Fire Alarm Control Panel Manual — P/N LS10147-002GF-E:E 06/11/2019
SLC Device Installation
Part Number
Model Name/Description
AMM-4SF
Addressable zone interface module
MMI-6SF
Six zone interface module
AOM-2SF
Supervised control module
MMO-6SF
Six circuit supervised control module I56-2740-00
ASD-PL3 / IV
Photoelectric smoke detector. white or
ivory
ASD-PL3R / IV
Photoelectric smoke with remote test
capability. white or ivory
ASD-PTL3 / IV
Photoelectric smoke detector with
thermal (135°F). white or ivory
ATD-L3 / IV
Programmable thermal detector. white
or ivory
ATD-L3R / IV
Rate-of-rise thermal detector with 135°
F fixed temperature. white or ivory
ATD-L3H / IV
Fixed high temperature thermal
detector (190°F). white or ivory
MCS-COF
CO Smoke Detector
B210LP
6" mounting base
B224BI / IV
6" isolator base. white or ivory
B224RB / IV
6" relay base. white or ivory
B200SR / IV
6" temporal sounder base. white or
ivory
B200S / IV
Intelligent Sounder Base. white or
ivory
B501
4" mounting base
B200SR-LF / IV Low Frequency Sounder Base. white
or ivory
B200S-LF / IV
Low Frequency Sounder Base. white
or ivory
MCS-PTIR
Photo/Thermal/IR Multi-Criteria
Install Sheet PN
I56-3552-00
I56-2742-00
I56-3550-00
I56-6535-00
I56-6536-00
I56-6535-00
I56-6537-00
I56-6537-00
I56-6537-00
I56-3872-00
I56-0595-00
I56-0725-00
I56-3737-00
I56-3392-00
I56-3387-00
I56-0357-00
I56-4152-00
I56-4151-00
I56-6620-00

Advertisement