Setting Maintenance Information - Makita TD Series User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 23

3-12. Setting Maintenance Information

This product keeps track of the Trigger count (the number of times the trigger switch is operated), the
Auto-Stop count (the number of times the Auto-Stop is activated) and the Impact time (Impact time).
You can set the following operations when condition 1 or condition 2 below is satisfied.
1. "Trigger count" or "Auto-Stop count" reached the number you set.
2. "Impact time" reached the time you set.
Settable items: LED indicator warning displays / tool operation prohibition / LED indicator warning displays
and tool operation prohibition
Use this feature for keeping track of product maintenance tasks.
When you click the "Read" button under "Maintenance information" the following window appears.
1. Total Information, Trip Information
This field displays the product's current work counts / time.
Click the "Trip Information clear" button to reset the Trigger count, Trip Auto-Stop count and Trip Impact time.
"Last maintenance date" shows the date and time when the most recent "Maintenance alarm / stop setting"
(see below) was carried out.
2. "Maintenance alarm / stop setting"
Set the timing for displaying the maintenance alarm / operation prohibition for the product.
Select "Alarm" from "Select Mode" to display the alarm only, and select "Alarm & Stop" from "Select Mode" to
display the alarm and operation prohibition. If "OFF" is selected, both the alarm display and the operation
prohibition will be disabled. Select "Trigger count" or "Auto-Stop count" from "Type", and enter the count
number to be displayed by the alarm into "Alarm Count", and enter the count number for prohibiting operation
into "Stop Count". For "Impact time", enter the time to display an alarm into "Alarm Time", and the time to
prohibit operation into "Stop Time".
Click "Write Setting in Tool" to transfer the settings to the product.
To close this window, click the Close button in the upper right corner of the window.
Important! Click "Write Setting in Tool" to transfer the settings to the product. If you only click "Trip
Information clear", the settings will not be transferred to the product.
Important! "Maintenance alarm / stop setting" settings cannot be entered unless you click "Trip Information
clear" and reset the "Trip Trigger count", "Trip Auto-Stop count", and "Trip Impact time".
Click the "Read" button under "Maintenance information" to configure
maintenance information.
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tw series

Table of Contents