Chapter 2 System Configuration; Overall Configuration - Mitsubishi Electric MELSEC Q Series User Manual

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

CHAPTER 2
This chapter describes a CC-Link/LT system configuration.
2.1

Overall Configuration

To one master station, up to 64 remote stations can be connected when the following conditions are met.
Transmission speed
Station-to-station distance
Maximum number of modules on a
branch line
Trunk line length
T-branch interval
Maximum length of a branch line
Overall branch line length
T-branch
connection
Terminating
resistor
*1
*2
*3
● Remote stations need not to be connected in station number order.
● Remote station numbers are not necessarily consecutive. (Leaving any station number out does not cause a data link
16
Downloaded from
ManualsNet.com
SYSTEM CONFIGURATION
Item
Trunk line length (The branch line length is not included.)
Master station
Branch
*3
line
Power
length
supply
adapter
*2
*1
Branch line length
Station-to-station
distance
Remote
station
The branch line length includes the length of *2.
The maximum length of the branch line and overall branch line length include the length of this item.
For the terminating resistor connection method,
error.)
search engine
Specifications
2.5Mbps
625kbps
No limit
8
35m
100m
No limit
4m
16m
15m
50m
T-branch interval length
Remote
Remote
Remote
station
station
station
Remote
station
Remote
station
Page 59, Section 4.5.4.
Remarks
156kbps
The cable length between terminating
500m
resistors at both ends (The branch
line length is not included.)
60m
The cable length per branch line
200m
Total length of all branch lines
Remote
Remote
Terminating
station
station
resistor
Remote
station
Trunk line
Remote
Branch line
station
*3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj61cl12

Table of Contents