Color Mode; Installation - emaux E-Lumen X Series User Manual

Hide thumbs Also See for E-Lumen X Series:
Table of Contents

Advertisement

3.2.4 Light Intensive chart
7.00m
6.00m
5.00m
4.00m
3.00m
2.00m
1.00m
0.00m

3.3 COLOR MODE

NO.
Mode
1
Cool White
2
Green
3
Blue
4
Green+Blue
5
Red+Green
6
Red+Green+Blue
7
Mode A: Blue+Gradual Red
8
Mode B: Green+Gradual Red

4. INSTALLATION

1. It is recommended to install a light every 20
2. The lights should be installed in the direction that they will not shine directly into the
house.
3. For training or competition pools, the lights must be installed on the sides in order to
prevent swimmers from seeing any glare.
4. Nothing should be placed on the pool side directly above the lights for ease of future
maintenance.
5. The cables connecting the lights and the transformers must be at least 6mm² and the
distance between them must not exceed 30m; otherwise the lights will not function
properly.
6. Terminal blocks must meet the IEC60988-2-1 standard having the rated connecting capacity
of 4,0mm² use of screw-type terminal at least 25A current rating, mounted on junction
boxes inside.
P6
INSTALLATION
TOPAZ
NO.
Mode
9
Mode C: Blue+Gradual Green
10
Mode D: RGB Color Sequence
11
Mode E: RGB Color Sequence
12
Mode F: Auto Color Change
13
Mode G: RGB Color Sequence
14
Mode H: Rapid Auto Color Change
15
Warm White
, the approximate exposure area of each unit.
Break Conduits
Above Waterline
Junction Box
D20 PVC pipe
TO
Transformer
Installation Step:
1. Opening Hole
TOP13-VS
TOP13-VL
3. Screw the nut tight from inside
Break Conduits
Above Waterline
Junction Box
TO
Transformer
2. Insert the light niche through the opening
with plastic ring on both face side.
O-ring
4. lead the power cord with connector though
the niche from the front side.
LAMP INSTALLATION
P11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Topaz

Table of Contents