INSTRUCTION MANUAL
COOL/DRY Model
KS2462R
Split System Air Conditioner
In order to protect the environment, this air conditioner uses the new refrigerant R410A.

Save These Instructions!

Printed on Recycled Paper
Pub. OI-85464189508000
©SANYO 2002

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo KS2462R

  • Page 1: Save These Instructions

    INSTRUCTION MANUAL COOL/DRY Model KS2462R Split System Air Conditioner In order to protect the environment, this air conditioner uses the new refrigerant R410A. Save These Instructions! Printed on Recycled Paper Pub. OI-85464189508000 ©SANYO 2002...
  • Page 2: Features

    Features This air conditioner is equipped with cooling and drying functions. Details on these functions are provided below; refer to these descriptions when using the air conditioner. Microprocessor Controlled Operation • The interior compartment of the remote control unit contains several features to facilitate automatic operation, each logically displayed for easy use.
  • Page 3: Table Of Contents

    Troubleshooting... 24 Operating Range ... 24 Product Information If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. Model No.
  • Page 4: Installation Location

    Otherwise there is a risk of suffocation in an extreme case. CAUTION Do not turn the air conditioner on and off from the power mains • switch. Use the ON/OFF operation button.
  • Page 5: Names Of Parts

    This illustration is based on the external appearance of a standard model. NOTE Consequently, the shape may differ from that of the air conditioner which you have selected. This air conditioner consists of an indoor unit and an outdoor unit.
  • Page 6: Unit Display And Operation Selector

    TIMER This section picks up infrared signals from the remote control unit (transmitter). This position is for operating the air conditioner with the wireless remote control unit. Set the selector normally in this position. Switch the selector to the OFF position if you are not going to use the air conditioner for a few days or longer.
  • Page 7: Remote Control Unit (Display)

    Remote Control Unit (Display) Displayed when main unit sensor is in use (1) Operation mode MILD DRY... COOL ... (2) Fan speed AUTO... HIGH ... MEDIUM... LOW... (3) Temperature setting 60 — 86 °F When set to 82 °F temperature indication ... OI-508-07EG “ROOM TEMP”...
  • Page 8: Remote Control Unit

    Press the buttons (TEMP .) Press the ON/OFF operation button This button is for turning the air conditioner on and off. Timer and Present Time First, press the program button to select the mode you want. setting buttons Each time you press the “HH” button, the hours advance by one.
  • Page 9 NOTE NOTE The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than ten minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature.
  • Page 10: Using The Remote Control Unit

    Remote Control Unit The remote control unit may be operated either from a non-fixed position or from a wall-mounted position. To ensure that the air conditioner operates Installation Position correctly, DO NOT install the remote control unit in the following places: DO NOT •...
  • Page 11 2) When taking out the remote control unit, pull it from the holder. Point the transmitter on the remote control unit at the sensor on the • indoor unit when operating the remote control unit and the air conditioner. Do not place objects which may block the transmitted signals between •...
  • Page 12: Operation With The Remote Control Unit

    ON position. Press the setting buttons as described below and change the settings as desired. To stop the air conditioner, press the ON/OFF operation button again. STEP 1 STEP 5 STEP 1 Press the MODE selector button and select the desired mode.
  • Page 13: Adjusting The Fan Speed

    Fan Speed A. Automatic Simply set the FAN SPEED selector button to the A microcomputer in the air conditioner automatically controls the fan speed when the the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level.
  • Page 14: Night Setback Mode

    Operation with the Remote Control Unit (continued) 3. Night Setback Mode The Night Setback Mode is used for saving energy. Press the NIGHT SETBACK button while the air conditioner is operating. To cancel the night setback function, press the NIGHT SETBACK button again.
  • Page 15: Special Remarks

    Special Remarks ‘‘DRY’’ ( ) Operation How it works? • • • • Power failure during operation Clicking Sound Clicking sound is • heard from the air conditioner • Remote Control Unit OI-508-15EG Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically.
  • Page 16: Setting The Timer

    1. How to set the (Example) To set to 9:10 pm. present time 2. How to set the OFF time (Example) To stop the air conditioner at 11:30 pm. Operation 1. Press the Program button ( three times. Press the HH button until PM 9 is •...
  • Page 17 Setting the Timer (continued) (Example) To start operation at 7:10 am. 3. How to set the ON time 4. How to set a program (Example) To start operation at 7:10 am. and stop the air conditioner at for daily ON/OFF operation Present...
  • Page 18: Setting The 1-Hour Off Timer

    Setting the 1-Hour OFF Timer 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. Setting procedure: Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button.
  • Page 19: Adjusting The Airflow Direction

    Adjusting the Airflow Direction 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. CAUTION When the humidity is high, the vertical vanes should be in the front position during the cooling or drying operation. If the vertical vanes are positioned all the way to the right or left, condensation may begin to form around the air vent and drip down.
  • Page 20: Operation Without The Remote Control Unit

    INDOOR UNIT If you have lost the remote control unit or it has trouble, follow the steps below. Operation If you want to turn on the air conditioner, switch the operation selector to the selector TEST OFF position, and then to the ON position.
  • Page 21 Care and Cleaning (continued) Anti-mold filter The anti-mold filter behind the air intake grille should be checked and cleaned at least once every two weeks. 1. Grasp both ends of the How to remove the anti-mold filter 2. Push the anti-mold Cleaning Use a vacuum cleaner to remove light dust.
  • Page 22 The air cleaning filter removes dust and dirt from the air, and reduces odors (not provided) and smoke from tobacco. The air clean filter is not provided with the air conditioner and must be purchased NOTE separately. Ask for the STK-F4B model when purchasing.
  • Page 23: Tips For Energy Saving

    Care and Cleaning (continued) Removing and remounting • the air intake grille CAUTION When using a footstool or the like, be careful not to let it tip over. Washing the grille with • water • Tips for Energy Saving Do not OI-508-23EG With the air intake grille open all the way, grip both arms with...
  • Page 24: Troubleshooting

    If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or service center. Trouble Air conditioner does not 1. Power failure. run at all.