How To Install The Indoor Unit; Remove The Rear Panel From The Unit; Make A Hole - Sanyo CH1872 Technical & Service Manual

Dc inverter split system air conditioner
Hide thumbs Also See for CH1872:
Table of Contents

Advertisement

3. How to Install the Indoor Unit

3-1. Remove the Rear Panel from the Unit

(1) Remove and discard the set screw on the rear
panel. (Fig. 6)
L L
(2) Press the 2
marks on the frame cover and disen-
gage the stationary tabs from the frame. (Fig. 7)
(3) Remove the rear panel.
NOTE
Tubing can be extended in 5 directions as shown in Fig.
8. Select the direction you need providing the shortest
run to the outside unit.
G
When left tubing is to be done, switch the drain hose
and drain cap. (For details, refer to "Switching drain
hose and drain cap" on page 14.)

3-2. Make a Hole

(1) Place the rear panel from the indoor unit on the wall
at the location selected. Make sure the panel is hori-
zontal, using a carpenter's level or tape measure to
measure down from the ceiling. Wait until after cut-
ting the hole before attaching the rear panel to the
wall.
(2) Determine which side of the unit you should make
the hole for tubing and wiring. (Fig. 9)
NOTE
In the case of left-rear tubing, use the measurement
points 2-3/8" (60 mm) from the edge of the rear panel for
precise placement of the hose outlet. (Fig. 9)
(3) Before making the hole, check carefully that no
studs or pipes are directly run behind the spot to be
cut.
Also avoid areas where elec-
CAUTION
trical wiring or conduits are
located.
The above precautions are also applicable if tubing
goes through the wall in any other location.
Set screw only for transportation
Left
tubing
Left-rear
tubing
2-3/8" (60 mm)
6
Fig. 6
Rear panel
marks
Fig. 7
Right-rear
tubing
(recommended)
Right tubing
Downward tubing
Fig. 8
Fig. 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents