Functions; Operation Functions; Functions 8-1. Operation Functions - Sanyo C1271 Technical & Service Manual

Dc inverter split system air conditioner
Table of Contents

Advertisement

8. FUNCTIONS

8-1. Operation Functions

Emergency operation
Emergency operation is available when the remote
controller malfunctions, has been lost, or otherwise
cannot be used.
To operate the system, press the OPERATION button,
which is also used as the receiver, below the unit display.
Each time this button is pressed, the OPERATION lamp
changes color to indicate the type of operation. Select the
desired type of operation.
COOL
(GREEN)
The set temperature is 4°F(2°C) below the detected room
temperature in the case of cooling operation.
SENSOR DRY operation
STOP
(Lamp Off)
37
SENSOR DRY
During DRY operation, the system adjusts the room
temperature and fan speed according to the conditions in the
room, in order to maintain a comfortable room environment.
DRY operation is as shown in the figure below.
Load
COOL zone
A zone
B zone
Conditions are monitored at all
times when the room temperature
is below 59°F(15°C).
DRY A
The compressor operation frequency varies.
The indoor fan operates with 1/f fluctuation.
DRY B
The compressor operates at a low operating frequency.
The indoor fan operates with 1/f fluctuation.
Monitor
Monitoring operation takes place when the room temperature
is below 59°F
15°C), or more than 5°F
(
temperature.
When the monitoring range is entered, the compressor stops,
and the indoor fan operates with 1/f fluctuation.
NOTE
(CLxx models only)
The Sensor Dry operation during the Low Ambient Cooling
Mode (outside air temperature:59°F(15°C) or lower) is as
follows.
DRY A
and
DRY B
The compressor operates a cycle of 3 minutes ON and 6
minutes OFF repeatedly.
PAM-
control
In order to further improve inverter performance, control is
switched between PWM control at low operation speeds, and
PAM control at high operation speeds, making the most
effective use of power.
3°C) below the set
(