Samsung RM255BABB Training Manual page 30

2 door 2 drawer convertible side by side refrigerator
Table of Contents

Advertisement

OPERATING INSTRUCTIONS & INSTALLATION
Error items of self-diagnostics
No
ITEM
1
I/M-SENSOR
2
R-SENSOR
DEFROSTING
3
SENSOR OF R
COMPARTMENT
4
R-FAN ERROR
I/M FUNCTION
5
ERROR
6
-
R-DEFROSTING
7
ERROR
8
CR SENSOR
DEFROSTING
9
SENSOR OF CR
COMPARTMENT
DEFROSTING
10
SENSOR OF CF
COMPARTMENT
CR-DEFROST
11
ERROR
CF-DEFROST
12
ERROR
WATER
13
HEATER ERROR
14
EXT-SENSOR
15
F-SENSOR
TROUBLE
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when the sensor
detected temperature is not lower than 122
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when the sensor
detected temperature is not lower than 122
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when the sensor
detected temperature is not lower than 122
AN error is displayed when there is a contact failure on the feedback signal
line, a motor wire missing or a defect of the motor itself, when operating the
relevant fan motor.
An error is displayed when there is bad horizontality and bad ice tray more
than twice for each item of the ice maker kit.
** Pertinent only to dispenser models (external attachment type).
Error occurs and is displayed when regarding the R compartment defrosting heater, there is an electric wire
cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is
displayed if defrosting is not finished after continuous heating for more than 70 min, for the R compartment.
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122
Electric wire cut, short-circuit, contact failure, missing of sensor housing , while in
case of display of defect by temperature, it is only displayed when sensor detection
temperature is not lower than 122 or not higher than -58
Error occurs and is displayed when regarding the CR compartment defrosting heater, there is an electric wire
cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is displayed
if defrosting is not finished after continuous heating for more than 70 min, for the CR compartment.
Error occurs and is displayed when regarding the CF compartment defrosting heater, there is an electric wire
cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is displayed
if defrosting is not finished after continuous heating for more than 70 min, for the CF compartment.
An Error is displayed in case of water heater housing missing or
electric wire cut.
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122
29
29
nor higher than -58
nor higher than -58
nor higher than -58
nor higher than -58
nor higher than -58
nor higher than -58
nor higher than -58
REMARK

Hide quick links: