Download Print this page

Acclaim Lighting X-Dimmer-3 PRO User Instructions page 2

Advertisement

-Master Mode
2.Manual Control Mode
In this mode, the dip-switch 10 is flipped to the "OFF" position,
Flip the dip-switch 1~3 to set the intensity of Red LEDs, dip-switch
4~6 to set the intensity of Green LEDs and dip-switch 7~9 to set
the intensity of Blue LEDs. Please refer to the following table for
further information.
DipSwitch Setting
Note:
In online operation, only one master X-Dimmer-3 PRO is allowed in a link. The master controls the slave
X-Dimmer-3 PRO and maximum 32pcs can be controlled.
*Please Note: Improvements and specifications in the design of the unit and the manual are subject to
change without any prior written notice.
All manuals and user guides at all-guides.com
Intensity
Red
Green
(SW1~3)
(SW4~6)
0
000
000
14%
100
100
28%
010
010
43%
110
110
57%
001
001
71%
101
101
86%
011
011
100%
111
111
1 2 3 4 5 6 7 8 9 10
Red
Blue
(SW7~9)
000
100
010
110
001
101
011
111
-2-
1 =
ON
0=
OFF
Green
Blue

Advertisement