Technical Description

4.1 Overview

The Q3 system is a modern workstation system designed for universal use in the dental
laboratory for processing crowns, bridges as well as plastic and model casting work. Q3 is
available in three different control variants: knee control (SK), foot control (SF) and table
control (ST).

4.2 Function description

The handpiece is used as a hand-held grinding or cutting tool. The maximum speed of the
handpiece is limited using the rotary knob on the control unit for the table and knee ver-
sions, and for the foot version using the max. Button on the front of the control unit.
Optionally, the QUBE or QUBE II control satellite can be connected. The preset and current
speeds are shown, as well as the limitation via the display and the touch-sensitive buttons.
Depending on the version, the speed is regulated variably via the knee plate, foot lever or
connected dynamic foot pedal (table version only).

4.3 Interfaces

The Q3 control units have the following interfaces to other machines:
Connection for controlling extraction systems. If the Q3 is operated on a KaVo SMARTair
stand-alone suction device or a Zubler suction point opener AP 501, the optional control
lines, item no .: 9229 (for KaVo) or item no. 9234 (for Freuding / Zubler) can be used to
connect and secure the switching signal.
Activation of the suction point signal:
 With the control switched on with the handpiece connected, press and hold the
button on the foot and knee unit for 4 seconds, and press and hold the button
on the table unit for 4 seconds.
 Confirmation via 2 x vibrations on the handpiece
Deactivation of the suction point signal in the same way.