• Data hold function • Relative zero mode • Auto power off and low battery indication • Backlight • Tilt Stand • CAT III 1000V • CAT IV 600V • Test Leads • Carrying Case OPERATOR’S MANUAL ORDER CODE: OXD-516-6487F cromwell.co.uk...
SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during Never apply voltage or current to the meter that exceeds the the operation of this Multimeter: • Do not use if the multimeter or test leads look damaged, or if you suspect that the Never apply voltage or current to the meter that exceeds the specified maximum: ...
Page 3
hazardous voltages. For maximum safety, the meter and its test leads should not be handled when these terminals are energized. CONTROLS AND JACKS PRODUCT FEATURES AUTO Ω μ ¡ ã ¡ ã Large 4000 count Liquid Crystal Display 1. Large 4000 count Liquid Crystal Display with symbolic signs with symbolic signs.
side of the part under test so the rest of the circuit n the display. The display will indicate the proper with the resistance reading. nd symbol. e in the display. The display will indicate the proper e and symbol. HECK d electric shock, never measure continuity on ve voltage on them.
Page 5
Range Resolution Accuracy 400.0mV 0.1mV +0.5% of rdg + 2 dgts 4.000V +1.2% of rdg + 2 dgts 40.00V 10mV 400.0V 100mV 1000V +1.5% of rdg + 2 dgts Input Impedance: 7.8MΩ. Maximum Input:1000V dc or1000V ac rms. AC Voltage (Auto-ranging except 400mV) AC Voltage (Auto ranging except 400mV) Range Resoluti...
Page 6
Resistance (Auto-ranging) Range Resolution Accuracy Resistance (Auto-ranging) Resistance (Auto-ranging) Resistance (Auto ranging) +1.2% of rdg + 4 dgts 400.0Ω 0.1Ω Range Resolution Accuracy Range Resolution Accuracy +1.0% of rdg + 2 dgts 4.000kΩ 1Ω +1.2% of rdg + 4 dgts 400.0Ω...
Page 7
Duty Cycle Range Resolution Accuracy 0.1%~99.9% 0.1% +1.2% of rdg + 2 dgts Pulse width: >100us, <100ms; Frequency width: 5Hz – 150kHz Sensitivity: <0.5V RMS Overload protection: 600V dc or ac rms. Diode Test Diode Test Test current Resolution Accuracy 0.3mA 1 mV +10% of rdg + 5 dgts...
2. Press the RELATIVE button to store the reading in the display and the "REL" indicator will appear on the display. 3. The display will now indicate the difference between the stored value and the measured value. Press the RELATIVE button to return to normal operation. Relative Button BACKLIGHT BUTTON The relative measurement feature allows you to make measurements relative to a stored reference...
Set the function switch to the VAC position. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (V) jack. Touch the test probe tips to the circuit under test. Read the voltage in the display.
RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit RESISTANCE MEASUREMENTS RESISTANCE MEASUREMENTS under test and discharge all capacitors before taking any resistance WARNING: To avoid electric shock, disconnect power to the unit WARNING: To avoid electric shock, disconnect power to the unit measurements.
CAPACITANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the power leads. Set the function switch to the CAP position. (“nF” and a small value will appear in the display). Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack (CAP).
& specifications. Assuring the quality and performance required by all sectors of industry. OXFORD PRECISION products are fully guaranteed against faulty materials & workmanship. Should they be found to be defective, they will either be repaired or replaced free of charge (fair wear and tear and/or misuse excepted).