  • Page 1 Osmio Infinity Hydroxy Gas/Water Production Electrolysis System User Manual Version 0.7 Telephone: 0330 113 7181...
  • Page 2 Disclaimer Osmio Solutions Ltd reserves the right to change its products and services at any time to incorporate technological developments. This manual is subject to change without prior notice as part of continuous product development. Although this manual has...
  • Page 3 Highly Flammable keep away from any surfaces or equipment that generate heat or static electrical sparks e.g. electric radiators, tongs Keep away the Osmio Infinity away from open flames, never use near a gas fire, gas cooker, open fire, or candles Combustible in air if Hydrogen gas concentration exceeds 4% Never use the Osmio Infinity while smoking –...
  • Page 4 OSMIO INFINITY SYSTEM USER MANUAL DATE VERSION NUMBER 06/02/2021...
  • Page 5: Table Of Contents

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Contents 1.0 Introduction ....................... 6 1.1 Intended Use ......................6 1.2 Principal of Operation .................... 7 2.0 Safety Precautions ....................7 2.1 Power Safety ......................8 2.2 Set Up ........................8 2.3 Operating the System ....................
  • Page 6 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM 6.6 Servicing the System Every 100 hours ..............35 6.7 How to Pack for 500 hour Service ............... 35 6.8 Preparing for Storage and Transportation ............36 7.0 Product Specifications .................... 37 7.1 General specifications ..................
  • Page 7: Introduction

    You have received this manual on successful completion of the required safety training. Your certificate is valid for 2 years and ongoing recertification is required. Osmio Solutions will contact you prior to the expiry of your certification to arrange this. Intended Use The Osmio Infinity Hydroxy Gas/Water Production Electrolysis System is designed to produce a gaseous mixture of hydrogen, oxygen, and electrically expanded water.
  • Page 8: Principal Of Operation

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Principal of Operation The system uses a catalyst and 0 total dissolved solid (TDS) water to produce gas by electrolysis. The catalyst is required to allow the electrical current to flow through the water and produce gas at the positive and negative electrodes.
  • Page 9: Power Safety

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Power Safety ● For use only with a standard UK 220 – 240 Volt three pin plug ● Plug into an earth bonded, RCD (Residual Current Device) protected circuit ●...
  • Page 10: Installation

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM ● Avoid static electricity sparks igniting the gas by discharging any static charge prior to operation (touch the system case before touching any of the containers or tubes that contain Hydroxy gas).
  • Page 11: Check Delivery For Completeness Or Damage

    ● Visually inspect the transport package, the system, and the accessories for any possible transport damage. ● If any parts are missing or damaged, contact Osmio Solutions Ltd within 48 hours If the system has been damaged contact Osmio Solutions Ltd to arrange shipment for replacement/repair.
  • Page 12: Environmental Conditions

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Tower cap to Humidifier - 1 tube (SO-676) Humidifier 1 to Humidifier - 2 tube (2002-7 2.1m) Spot applicator Eye applicator (goggles) Nasal Cannulas Plastic funnel Power cord 50 ml syringe...
  • Page 13 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Place on a surface that is flat, dry, clean, vibration-proof, and leave additional ● room for cables, tower cap, and so on Ensure there is sufficient room to enable disconnecting the device ●...
  • Page 14: System Parts And Accessories

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM System parts and accessories Main Power Switch TDS Meter Timer Switch Handles Frequency Buttons Gloves Duty Cycle Buttons 50 ml Syringe Green Gas Production Light Nasal Cannula Red Over-Full Liquid Level...
  • Page 15: Assembly Instructions

    You will require approximately 3.5 litres of 0 TDS water which can be produced in a number of ways ● Filter 4 litres of water using the Osmio Zero and place in a distiller and distil for 4 hours (If distilling filtered water please ensure you follow the manufacturer’s instructions and descale the distiller regularly as directed) ●...
  • Page 16 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Step 2 Prepare the electrolyte solution (skip this if premixed lye solution is supplied) ● Make sure your work area is well ventilated and work surface is covered ● Put on safety glasses, gloves, and mask ●...
  • Page 17 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM ● Repeat with the two screws at the front of the top of the system, place handle in place and screw in position using the screws ● Unscrew black fill cap from the system and prepare the exposed threads by...
  • Page 18 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Lye solution should only be put in the machine using the funnel provided. The tower cap should only be removed for the initial lye fill and for maintenance. Do not overfill the system (maximum of 1250 ml on first fill). Fill to 100% ‘’Full’’...
  • Page 19: Performing The Operational Check

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM When attaching the tubes do not push the tubes too far, only push on tight enough to seal. You should only have to rock & twist the tube gently to remove it.
  • Page 20: Relative Contraindications

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM 3.8 Mechanical Timer Please follow these instructions to operate mechanical timer. ● The timer has to be turned clockwise past 10 minutes for the system to start producing gas ●...
  • Page 21: Gas Volume And Calculating The Duty Cycle

    ● Women generally have 20% less lung capacity than men of the same weight To calculate your safe breathing limit the following is taken into consideration: ● The Osmio Infinity makes up to 50 litres of HydrOxy gas per hour (lph) ● HydrOxy gas is two thirds (2/3 or 0.6666) hydrogen.
  • Page 22 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Divide body weight (if overweight/underweight use ideal body weight) in lbs by 5 e.g. 180 lbs / 5 = 36% Or for metric Divide body weight (if overweight/underweight use ideal body weight) in kg by 2.3 e.g.
  • Page 23 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Estimated Duty Cycle (%) vs Gas Volume Production (l/hr and ml/m) Chart l/hr ml/m l/hr ml/m l/hr ml/m l/hr ml/m 13.0 25.5 38.0 13.5 26.0 38.5 14.0 26.5 39.0 14.5...
  • Page 24 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM 21.5 34.0 46.5 22.0 34.5 47.0 10.0 22.5 35.0 47.5 10.5 23.0 35.5 48.0 11.0 23.5 36.0 48.5 11.5 24.0 36.0 49.0 12.0 24.5 37.0 49.5 12.5 25.0 37.5 50.0...
  • Page 25 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM 27.2 83.9 18.5 30.0 86.2 19.0 31.8 88.5 19.5 34.0 90.7 20.0 36.3 93.0 20.5 38.6 95.3 21.0 40.8 97.5 21.5 43.0 99.8 22.0 45.4 10.0 102.0 22.5 47.6 10.5...
  • Page 26 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Example ● Adult male ● 220 lbs ● Ideal weight 180 lbs ● Breathing 0.5 litres (500 ml) of air every 3 seconds 500 ml x 0.02 = 10 ml 10 ÷...
  • Page 27: Operating The System

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Operating the System Hydroxy gas can be inhaled through a nasal cannula or used topically for localised body ailments. Gas can also be bubbled in a foot bath or bathtub using the additional tubing and bubbling stone.
  • Page 28: Drinking Water

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Never breathe gas that has not gone through BOTH Humidifiers which have been filled to the respective fill lines. Always replace the water in the Humidifiers with 0 TDS/Distilled water.
  • Page 29: Shutting The System Off

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Shutting the System Off When you are finished using the system turn off at the main power switch. It is safe to leave the system plugged in when not producing gas.
  • Page 30: Maintenance

    The system requires regular and preventative maintenance to prevent damage to the system and ensure the safety of the users, please contact Osmio Solutions Ltd for assistance if necessary. This section contains an outline of the points mentioned in the checklist below.
  • Page 31: Maintenance In The Home

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Maintenance in the Home Maintenance Checklist - Home Setting Daily (or after each user) Visual Checks Check all parts are present and securely fitted (do not overtighten) Check the fluid levels (System, Humidifier - 1 and Humidifier - 2)
  • Page 32: Cleaning Nasal Cannulas (Home Use)

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM 6.2 Cleaning Nasal Cannula and Tubing (home use) 6.2.1 Cleaning cannula and tubing Nasal cannulas and tubing require to be cleaned after each use (or daily if system used several times a day).
  • Page 33: Maintenance In A Clinical Setting

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Maintenance in a Clinical Setting The system and tubing will require regular disinfection in a clinical setting. Please liaise with your infection control and risk management staff to ensure that disinfection is carried out regularly and documented.
  • Page 34: Changing The Humidifier Water

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Cleaning Switch off, unplug, and clean the outside of the system with a suitable disinfectant, allowing the unit to dry before use Disinfect the tubing (see section 8.1) Visual Check...
  • Page 35 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM ● Do not ever plug or cap the check valve(refill valve in the tower) or it will not be able to mitigate the electrolyser vacuum ● Tilt system back and forward to check if the ball in sight tube is moving ●...
  • Page 36: Servicing The System Every 100 Hours

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Servicing the System Every 100 hours 1. Remove tubing from Tower Cap 2. Remove Humidifier - 1 from the bracket 3. Remove the tower cap from the top of the system 4.
  • Page 37: Preparing For Storage And Transportation

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM 8. Immediately clean up any spilled lye with lots of water until the ‘slippery’ feeling is gone 9. Once fully drained sit upright and refit the black top cap to the top of the system 10.
  • Page 38: Product Specifications

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Product Specifications Osmio Solutions Ltd reserves the right to change any specifications without prior notice as part of our continuous product development program. General specifications General Specifications Overall Dimensions...
  • Page 39: System Specifications

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM System Specifications CE safety declared Built to CSA/UL and Australian safety standards Master power switch (total shut off) Easy to use timer switch Continuous run operation Electronically adjustable gas volume output (DUTY 1% to 100%)
  • Page 40: Troubleshooting Guide

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Troubleshooting Guide Most issues with the Osmio Infinity can be resolved by the user. There are few mechanical (manufacturer) issues with the system because each one is thoroughly tested before being shipped and is designed for a 20 year service life. Issues with the system can generally be resolved by ensuring the machine is set up properly.
  • Page 41 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Red low level light is on and The liquid level is too low, top it up with the water alarm is sounding from Humidifier - 1 and ensure Humidifier - 1 is topped back up to the fill line with 0 TDS/distilled water before use.
  • Page 42 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM The green gas production light There are two causes: comes on and stays on, but you A Not enough gas production have low or no gas being B A gas leak...
  • Page 43: Glossary Of Terms

    Gently screw the tower cap back on ensuring not to overtighten. Please do not remove the case of the Osmio Infinity unless specifically instructed to do so. There are no serviceable parts inside and there is danger of electrical shock.
  • Page 44: Appendix A - Medical Disclaimer

    Even though we use only natural ingredients, always check with our doctor for risks associated with dietary supplements and how they relate to your specific health conditions and/or allergies. The Osmio Infinity is not yet defined as a medical device.
  • Page 45: Appendix B - System Maintenance Log

    USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Appendix B - System maintenance log DATE HOURS SIGNATURE PRINT AND SIGN RETURN SYSTEM FOR MAINTENANCE 1000 RETURN SYSTEM FOR MAINTENANCE 1100 1200 1300 1400 1500 RETURN SYSTEM FOR MAINTENANCE...
  • Page 46 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM DATE HOURS SIGNATURE PRINT AND SIGN...
  • Page 47 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Turn on the system ☐ Discharge any static electrical charge by touching the system case ☐ Check the liquid level is not too low ☐ Top up liquid from Humidifier 1 if required ☐...
  • Page 48: Appendix D - Frequently Asked Questions

    NO. NEVER breathe the HydrOxy gas or use it for any other health purpose unless it has first gone through both Humidifiers. Do I need to keep touching the metal casing while I am using the Osmio Infinity? Not unless you do something that will generate static electricity, like stroking a pet or shuffling across the carpet.
  • Page 49 USER MANUAL FOR THE OSMIO INFINITY HYDROXY GAS/WATER PRODUCTION ELECTROLYSIS SYSTEM Contact Details Osmio Solutions Ltd Buckland Lake Reserve Buckland Road Cliffe Nr Rochester ME3 7RT Telephone: 0330 113 7181 Email: info@osmiowater.co.uk www.osmiowater.co.uk...