ERROR MESSAGES
Error No.
E-64
The take-up reel motor speed is abnormally high.
E-65
Abnormal tension has been detected.
E-66
At the tape start or end, the short FF or REW operation does not stop even after 7
or more seconds.
E-67
A check sum error was detected in the serial data communication between the
syscon and servo.
E-68
In serial data communication between the syscon and servo, the data was fixed at
low or high and the absence of data was detected.
E-69
A communication error was detected in the serial data between the syscon and
servo when the power was turned on.
E-70
About an hour has elapsed after the fan motor stopped. The VTR forcibly turns off
its power.
E-71
The heat sensor was activated and an abnormally high temperature inside the
VTR was detected.
E-72
Trouble in the solenoid drive circuitry was detected.
E-73
Trouble in the cleaning solenoid drive circuitry was detected.
E-BA
The input supply voltage dropped below the undercut voltage.
(*) The counter display flashes to provide a warning.
Details of error
70
VTR operation
STOP
STOP
STOP
STOP
STOP
STOP
Forced POWER OFF
Forced POWER OFF
Forced POWER OFF
Forced POWER OFF
Forced POWER OFF (*)