DETAILED DESCRIPTION OF SET-UP MENUS
INTERFACE
Item
No.
Item
No.
200
ID SEL
0000
0001
201
LOCAL ENA
0000
0001
202
OPTION MODE
0000
0001
0002
0003
203
BAUD RATE
0000
0001
0002
0003
0004
204
DATA LENGTH
0000
0001
205
STOP BIT
0000
0001
206
PARITY
0000
0001
0002
207
FLOW
0000
CONTROL
0001
208
EDL FORMAT
0000
0001
The underlined number and item are the factory settings.
Setting
Item
This selects the ID information which is to be returned to the controller.
OTHER
DVCPRO
0: 20 25H
1: The ID (F0 33H) unique to DVCPRO is returned.
This selects the switches which can be operated on the front panel when the
DIS
ST&EJ
REMOTE/LOCAL switch is at REMOTE.
0: None of the switches or buttons can be operated.
1: Only the STOP (ALL STOP) and EJECT buttons can be operated.
EDL
This sets the EDL connector (9P) mode.
0: For dumping/loading EDL data.
AMU1
AMU2
1: The audio memory unit is used under the audio dubbing specifications.
2: The audio memory unit is used under the audio channel 2 fade specifications.
AMU3
3: The audio memory unit is used under the audio channel 1 fade specifications.
This sets the baud rate when EDL is set for set-up menu item No.202
1200
(OPTION MODE).
2400
4800
9600
19200
This sets the data length when EDL is set for set-up menu item No.202
7
8
(OPTION MODE).
1
This sets the stop bit when EDL is set for set-up menu item No.202 (OPTION
MODE).
2
This sets the parity when EDL is set for set-up menu item No.202 (OPTION-
NON
ODD
MODE).
EVEN
This enables or disables the flow control for the EDL data communication.
NONE
RTSCTS
0: Flow control using RTS/CTS is disabled.
1: Flow control using RTS/CTS is enabled.
This sets the format with which EDL data is to be dumped.
AGA850
CMX340
0: Format common with Matsushita's AG-A850.
1: Format common with the CMX340 editing system.
Description of setting
26
V
V
T
T
R
R
1