09/10/09
CAS (USA) Corporation 99 Murray Hill Parkway East Rutherford, NJ 07073
PROGRAMMING LBS/OZ FOR PD-II CAL MODE OPTIONS
1.
Make sure that the scale is off. Remove the platter. Remove the calibration bolts and plate
located on the top front of the scale.
2.
After removing the calibration bolts and plate you will see a white micro switch at the bottom of
the hole. Press and hold down the micro switch and turn on the scale.
The display will read "CAL" → "Ver XXX "→ "C-0 ". Release the micro-switch. Press the [ # ]
3.
key until the display shows "C-4 ". Replace the platter. ( " # " is to increase and "lb/oz" is to
decrease the value )
Press the [ ZERO ] key and display should read "C41 XX ". Press [ ZERO ] to go to the next
4.
step " C42 XX " → " C43 XX " → " C44 XX " → " C45 XX " → " C46 XX ".
Depending on the capacity and function, enter the value "XX "step by step. Press "# "to move
5.
the digit and "* or lb/oz " to change the value. ( see chart below)
Note: For the setting "C42" for all capacities single range is "38" and dual range is what is in the
6.
chart below.
7.
The settings for the capacity and single/dual range must follow what is on the serial number plate
or else the scale will not be NTEP or legal for trade subject to a fine by Weights and Measures.
C41
C8
d0
C8
D0
15lb/300oz
C41
C42
C43
C44
C45
C46
Press the [ ZERO ] key. Display shows "C4 End "then "C-4 ".
8.
Press "* or lb/oz "until the display shows "C-0 ".
9.
C44
80
80
00
00
30lb/600oz 60lb/1000oz
C8
C8
1A
3A
00
00
80
80
00
00
00
00
What the scale does
Starts up in lb and can be switched to oz
Starts up in oz and can be switched to lb
Starts up in lb and will not switch to oz
Starts up in oz and will not switch to lb
C8
4A
00
80
00
00
PD-II
150lb/2000oz
C8
62
00
80
00
00
Need help?
Do you have a question about the PD-II and is the answer not in the manual?
Questions and answers