Unilamp XEON Cross Installation Manual

Advertisement

INSTALLATION MANUAL
PRODUCT NAME : XEON Cross - Wall Light,
XEON Roof - Wall Light , XEON Flat - Wall Light
No.
Input voltage
1.
220-240V 50-60Hz (with sensor)
2.
3.
203
XEON Cross - Wall Light
1
1.2
1.4
1.1
Last Revised On : 23/11/2020 REV.05
Ordering Code
7026/7027/7028-0-3-956-XX
7026/7027/7028-0-3-957-XX
7026/7027/7028-0-3-610-XX
142
1.3
1.5
Open
ແ ´
IP65
203
130
XEON Roof - Wall Light
Wall plug anchor size
2
L
Ø
7
mm./ÁÁ.
2.2
2.1
1/7
1-3
Light Emitting Diodes
(LED)
203
XEON Flat - Wall Light
¢¹Ò´¾ÅØ  ¡ ½˜ § ¼¹Ñ §
D
L
L
37
mm./ÁÁ.
2.3
Torque/áçºÔ ´ : 1.0 Nm.
FR-DM-17 REV.03 EFF 15/09/17
77
Screw size
¢¹Ò´Ê¡ÃÙ à ¡ÅÕ Â Ç»Å‹ Í Â
D
L
Ø
4
mm./ÁÁ.
38
mm./ÁÁ.
105

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XEON Cross and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Unilamp XEON Cross

  • Page 1 INSTALLATION MANUAL PRODUCT NAME : XEON Cross - Wall Light, XEON Roof - Wall Light , XEON Flat - Wall Light IP65 Input voltage Ordering Code 220-240V 50-60Hz (with sensor) 7026/7027/7028-0-3-956-XX 7026/7027/7028-0-3-957-XX 7026/7027/7028-0-3-610-XX Light Emitting Diodes (LED) XEON Cross - Wall Light...
  • Page 2 Close » ´ Cable size : 3x1.00 mm. ∅ 6-10 mm. ¢¹Ò´ÊÒÂä¿ Lock the screws following this sequence. ¤ÇÃ¢Ñ ¹ Ê¡ÃÙ µ ÒÁ Åí Ò ´Ñ º ¢Í§ËÁÒÂàÅ¢ ·Õ è Ã ÐºØ ä ÇŒ µ ÒÁÃÙ » ÀÒ¾ Installation complete Torque : 1.0 Nm.
  • Page 3 Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm. 6-10 mm. Ø Any damaged safety glass cover must be replaced only with the original spare part. àÁ× è Í ¡ÃШ¡à¡Ô ´ ¤ÇÒÁàÊÕ Â ËÒ à¾× è Í ¤ÇÒÁ»ÅÍ´ÀÑ Â ¤ÇÃÊÑ è § ÍÐäËÅ‹ á ·Œ ¨ Ò¡¼Ù Œ ¼ ÅÔ µ à·‹ Ò ¹Ñ é ¹ Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires.
  • Page 4 HI-LOW LIGHT FUNCTION SETTING FOR LUMINAIRE WITH SENSOR ¡ÒÃµÑ é § ¤‹ Ò ¤ÇÒÁÊÇ‹ Ò §Êí Ò ËÃÑ º â¤Á·Õ è Á Õ à «¹à«ÍÏ Option/µÑ Ç àÅ× Í ¡ I Brightness Brightness ¤ÇÒÁÊÇ‹ Ò § ¤ÇÒÁÊÇ‹ Ò § 100% Option/µÑ...
  • Page 5 PARAMETER SETTING OF MICROWAVE SENSOR ¡ÒÃµÑ é § ¤‹ Ò ¢Í§à«ç ¹ à«ÍÏ 1 2 3 1 2 3 4 1 2 3 4 Detection range setting (sensitivity) ¡ÒÃµÑ é § ¤‹ Ò ÃÐÂеÃǨ¨Ñ º ¡ÒÃà¤Å× è Í ¹äËÇ This determines the effective range of the motion detector set by DIP switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range.
  • Page 6 MASTER/SLAVE FUNCTION/Ãкº¤Çº¤Ø Á ¡Ò÷í Ò §Ò¹â´Ââ¤Á·Õ è Á Õ à «¹à«ÍÏ 1 µÑ Ç Option A/µÑ Ç àÅ× Í ¡A Controled by using 1 luminaire with sensor to control luminaire without sensor up to 26 fittings. ¡ÒÃ㪌 â ¤Á·Õ è Á Õ à «¹à«ÍÏ Ë ¹Ö è § µÑ Ç ¤Çº¤Ø Á â¤ÁẺäÁ‹ Á Õ à «¹à«ÍÏ ÊÒÁÒöµ‹ Í ¾‹ Ç §ä´Œ Ê Ù § ÊØ ´ 26 â¤Á Cable connection/¡Òõ‹...
  • Page 7 MASTER/SLAVE FUNCTION/Ãкº¤Çº¤Ø Á ¡Ò÷í Ò §Ò¹â´Ââ¤Á·Õ è Á Õ à «¹à«ÍÏ 2 µÑ Ç Option B/µÑ Ç àÅ× Í ¡ Controled by using 2 luminaire with sensor to control luminaire without sensor up to 26 fittings. ¡ÒÃ㪌 â ¤Á·Õ è Á Õ à «¹à«ÍÏ Ê Í§µÑ Ç ¤Çº¤Ø Á â¤ÁẺäÁ‹ Á Õ à «¹à«ÍÏ ÊÒÁÒöµ‹ Í ¾‹ Ç §ä´Œ Ê Ù § ÊØ ´ 26 â¤Á Cable connection/¡Òõ‹...

This manual is also suitable for:

Xeon roofXeon flat

Table of Contents