Advertisement

Quick Links

Yscope
User's Manual
Yscope User's Manual for Measurement Guide and Setup
Thank you for purchasing the Yscope. This user's manual describes all the features of the Yscope.
Please read before use and keep it in a safe place. By following properly these instructions, you will be able to use the
Yscope more safely and effectively.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Yscope and is the answer not in the manual?

Questions and answers

Summary of Contents for inbody Yscope

  • Page 1 Yscope User’s Manual for Measurement Guide and Setup Thank you for purchasing the Yscope. This user's manual describes all the features of the Yscope. Please read before use and keep it in a safe place. By following properly these instructions, you will be able to use the...
  • Page 2 Visceral fat also plays a key role in the development of metabolic and cardiovascular disease. * The Yscope is not a diagnostic device. To make an accurate diagnosis, a physician must go through a thorough examinations and take their results into account in addition to the results of the Yscope.
  • Page 3 Visit our website inbody.com to view and download further information about the functions of the Yscope the explanation of results output, and more. InBody Co., Ltd. reserves the right to modify the appearance, specifications, and etc. of the Yscope to improve the quality of the product, without prior notice for reasons of performance improvement.
  • Page 5: Table Of Contents

    Yscope User's Manual Contents I. Yscope Installation A. Product Components B. Installation Environment C. Installation Instructions D. Connecting to InBody E. Preference F. Precautions for Maintenance II. Abdominal Impedance Measurement A. Precautions for Measurement B. Measuring Posture and Measuring Method III.
  • Page 6: Product Components

    A. Product Components The Yscope consists of the following components. Make sure all of the components are present. * Please check each component of the system for damage prior to installation. If you have any issues, contact our Product Support team.
  • Page 7: Installation Environment

    B. Installation Environment Check that the environment is suitable before installing the Yscope. This device is suitable for indoor use. If installing this equipment outdoors, the following requirements must be met: Temperature range 10 ~ 40°C (50 ~ 104°F) Relative humidity...
  • Page 8 • Install the charging station on a flat and vibration-free floor. • If installed on an uneven floor, there is a risk of the Yscope dropping if the charging station falls or shakes. • If the charging cable is not inserted into the rubber groove, the cable may be damaged, causing problems with the product, and the charging station may shake.
  • Page 9 Warning • Do not place the Yscope in contact with other electronic devices while connected to power, as it may cause an electric shock. • Do not plug in or unplug the power cable with wet hands, asit may cause an electric shock.
  • Page 10: Connecting To Inbody

    • The product button is disabled during charging. • If you operate the buttons on the Yscope from the charging station, the product may drop and break. • The battery can be fully discharged if it is kept separate while the power is on.
  • Page 11: Preference

    4. When synced with the InBody, the connection display appears at the top and the center of the InBody's screen, as shown below. Example of Bluetooth connection E. Preferences This product lets you choose unit settings and audio notification settings under Preferences. No Pacemaker 1.
  • Page 12: Precautions For Maintenance

    • Do not arbitrarily disassemble the product. It can cause electrical shock or injury, product failure, or errors in measurement. • InBody is not responsible for any damages and related losses to Yscope caused by the user's tampering. • Do not use it for purposes other than the measurements presented in this user manual.
  • Page 13: Abdominal Impedance Measurement

    • You can check the battery charge status by the battery level indicator on the upper right of the standby screen. • Please check the sync status with the InBody. • The sync status can be checked via the display on the InBody screen. Example of Sync Status with InBody...
  • Page 14: Measuring Posture And Measuring Method

    2. Wet the side of the subject with an InBody Tissue (or wet tissue) and place the electrode on the measurement area. Push it so that all the electrodes in the product are attached to the measurement area. All electrodes must be in full contact with the abdomen to achieve accurate measurements.
  • Page 15 4. When the measurement is completed, "Complete" is displayed on the screen along with a 'beep' sound. When the measurement is completed by pressing the button on the product, the measured data will be transferred to the linked InBody device. After transmission, the device automatically switches to waist circumference measurement mode.
  • Page 16: Waist Circumference Measurement

    Waist Circumference Measurement III. A. Precautions for Measurement Caution • Please wear comfortable clothing during measurement. • For accurate waist circumference measurement, do not wear heavy clothing or accessories. • Please measure the subject while they are standing as straight as possible. •...
  • Page 17 InBody device. * Since the Yscope estimates the total waist circumference by measuring the waist circumference of the right half of the body, it may be different from the actual waist circumference.
  • Page 18: Cautions During Transportation

    Transport and storage A. Cautions during Transportation To transport the Yscope safely, two people should keep the equipment in a horizontal position. B. Repacking Instructions 1. Press and hold the button and the button simultaneously (3-5 seconds) to turn off the power.
  • Page 19: Frequently Asked Questions (Faq)

    • This may be caused by dry electrode contact with the stomach. In this case, wipe the contact area with an InBody Tissue or wet tissue. • Check the installation location of the Yscope. Do not install the device near fluorescent lights, large AC motor equipment (such as running machines, shaking equipment, refrigerators, air conditioners, and compressors), or high-frequency heat treatment equipment or heaters, as test results may be inaccurate due to the effects of electromagnetic waves.
  • Page 20 If the measurement is performed without maintaining the proper pressure, the impedance progress. value may be inaccurate, so please observe the measurement method. Since the Yscope estimates the total waist circumference by measuring the waist • The waist circumference value is •...
  • Page 21: Others

    Others * The Yscope was produced following InBody's quality control procedures. InBody Co., Ltd. complies with international quality systems ISO9001 and ISO13485. * This equipment meets IEC60601-1 (EN60601-1), the international safety standard for electronic medical equipment. The equipment also meets the IEC60601-1-2 (EN60601-1-2), the international standard for electronic conformity.
  • Page 22: Safety Information

    2. Charging station Charging terminal: Accepts the Yscope main unit for charging ❶ Mounting magnet: Component that orients the Yscope in a fixed position ❷ Cable groove: Organizes the cable to the bottom of the station ❸ ❷ ❶ ❸...
  • Page 23: Product Classification

    Color White Dimension Yscope: 126.7(W) × 269.3(L) × 63.5(H) mm (5.0(W) × 10.6(L) × 2.5(H) in) Charging station: 260 X 260 X 790 mm (10.2 × 10.2 × 31.1 in) Equipment Weight Main unit 0.3 kg (0.7 lb), Charging station 2.5 kg (5.5 lb)
  • Page 26 1639 ©2021 InBody Co., Ltd. All rights reserved. IM-ENG-L1-C-211105...