Product Data Sheets - KitchenAid Side By Side Built-In Refrigerator Use And Care Manual

Side by side built-in refrigerator
Hide thumbs Also See for Side By Side Built-In Refrigerator:
Table of Contents

Advertisement

Available languages

Available languages

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50%
*
Particulate Class 1
85%
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.01mg/L
Lead: @ pH 8.5
0.01mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-dichlorobenzene
0.075 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
2, 4-D
0.07 mg/L
Asbestos
99%
Cysts‡
99.95%
Turbidity
0.5 NTU
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-LC400V The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400V, part
#4396548. 2006 suggested retail price of $39.99 U.S.A./
$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
*
Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
**
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
††
20

PRODUCT DATA SHEETS

Base Grille Water Filtration System
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
Tested and certified by NSF International against ANSI/NSF Standard 42 for the
reduction of Chlorine Taste and Odor, Particulate Class I*; and against
ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,
Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.
Average
Influent
2.1 mg/L
5,366,667/mL
Average
Influent
0.152 mg/L†
0.143 mg/L†
0.0061 mg/L
0.0057 mg/L
0.0162 mg/L
0.220 mg/L
0.014 mg/L
0.0086 mg/L
0.197 mg/L
26 x 10
7
111,000/mL
11.00 NTU
Influent Challenge
Maximum
Concentration
Effluent
2.0 mg/L ± 10%
0.06 mg/L
At least 10,000
4,100/mL**
particles/mL
Influent Challenge
Maximum
Concentration
Effluent
0.15 mg/L ± 10%
0.001 mg/L
0.15 mg/L ± 10%
0.001 mg/L
0.006 mg/L ± 10%
0.0004 mg/L
0.0058 mg/L ± 10%
0.0008 mg/L
0.015 ± 10%
0.0005 mg/L
0.225 ± 10%
0.0005 mg/L
0.015 ± 10%
0.0014 mg/L
0.009 mg/L ± 10%
0.0005 mg/L
0.210 ± 10%
0.058 mg/L
10
7
to 10
8
fibers/L††
0.18 x 10
50,000/L min.
1 mg/L
11 ± 1 NTU
0.40 NTU
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average
Minimum %
Effluent
Reduction
0.05 mg/L
97.1%
2,300/mL
99.3%
Average
Minimum %
Effluent
Reduction
0.001 mg/L
99.34%
0.001 mg/L
99.30%
0.0003 mg/L
93.5%
0.00051 mg/L
85.8%
0.001 mg/L
96.3%
0.0005 mg/L
99.7%
0.001 mg/L
90%
0.0005 mg/L
94.25%
0.0137 mg/L
70.6%
7
mg/L
0.18 x 10
7
mg/L
99.93
1 mg/L
99.99%
0.35 NTU
96.4%
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.89 L/min.) @ 60 psi.
Average %
Reduction
97.6%
99.9%
Average %
Reduction
99.34%
99.30%
96.7%
91.2%
96.3%
99.7%
92.96%
94.25%
93.06%
99.93%
99.99%
96.8%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents