Data
Item
No.
Total Plug-in Time
03
04
Total Combustion Time
05
Total Combustion Time
Number of Ignition Times
07
Number of Ignition Times
08
Fan Rotational Frequency
10
14
Total Flow Rate
State of water level electrode 1, 2
19
Water Inlet Thermistor
30
Detection Temperature
Water Outlet Thermistor
31
Detection Temperature
Heat Exchanger Thermistor
32
Detection Temperature
Exhaust Thermistor
36
Detection Temperature
Air Inlet Thermistor
38
Detection Temperature
Error Code History 1
91
Error Code History 2
92
Error Code History 3
93
Error Code History 4
94
Error Code History 5
95
Error Code History 6
96
Error Code History 7
97
Error Code History 8
98
Data
Minimum
(Display Reading X Multiplier)
Value for
Multiplier
Unit
Indication
X 100
hour
100 hour
X 1
hour
1 hour
X 1000
hour
1000 hour
X 10
time
10 times
X 10000
time
10000 times
rpm
25 rpm
X 10
X 0.1
L/min
0.1L/min
000
001
010
011
X 0.1
°C
0.5°C
X 0.1
°C
0.5°C
X 0.1
°C
0.5°C
X 1
°C
1°C
X 1
°C
1°C
Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
- 45 -
Remarks
Disp. Range [000] - [1310]
Disp. Range [000] - [999]
Disp. Range [000] - [1999]
Disp. Range [000] - [999]
Disp. Range [000] - [1999]
1=OFF 2=OFF [000] , 1=ON 2=OFF [001]
1=OFF 2=ON [010] , 1=ON 2=ON [011]
< Condensing Model only >
< (L)WHiC56 only >
If the same error code is repeated,
it will appear in the history list
twice. If it is repeated more than
twice, it will only appear twice.