G.F.C.I. receptacle test
1. Start the engine.
2. Turn the AC switch (N.F.B.) to "I" (ON).
3. Press the test button, then check the position of
1 Reset button
2 Test button
1
2
000-000
4. If G.F.C.I. operation is correct, push in the reset
763-059
Do not operate the generator with a faulty G.F.C.I.
circuit. Electric shock could occur. Have the gener-
ator repaired by a qualified mechanic.
the reset button.
G.F.C.I. reset
button position
after test
Pop out
3
Stay in
4
button.
If the G.F.C.I. operates incorrectly, consult a
Yamaha dealer.
WARNING
– 43 –
G.F.C.I. receptacle
operation
Correct
Incorrect