Shodex RSpak KC-811 Operation Manual

Shodex RSpak KC-811 Operation Manual

Advertisement

Operation Manual Shodex RSpak KC-811 and KC-811 6E
Shodex™ RSpak™ KC-811 and KC-811 6E
Europe, Middle East, Africa, Russia
www.shodex.de
Operation Manual
Sales Office:
Showa Denko Europe GmbH
Shodex Business
Konrad-Zuse-Platz 3
81829 Munich
Germany
Version 2020
Technical Support:
info@shodex.de
+49 (0)89 / 93 99 62 37
Quotes and Orders:
order@shodex.de
+49 (0)89 / 93 99 62 34

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSpak KC-811 and is the answer not in the manual?

Questions and answers

Summary of Contents for Shodex RSpak KC-811

  • Page 1 Operation Manual Shodex RSpak KC-811 and KC-811 6E Version 2020 Operation Manual Shodex™ RSpak™ KC-811 and KC-811 6E Sales Office: Technical Support: Showa Denko Europe GmbH info@shodex.de Shodex Business +49 (0)89 / 93 99 62 37 Konrad-Zuse-Platz 3 81829 Munich...
  • Page 2: Handling Instructions

    Version 2020 Operation Manual Shodex™ RSpak KC-811 and KC-811 6E (Thank you for purchasing a Shodex product. Prior to use, be sure to read this instruction manual so that the maximum service life and performance can be achieved.) Introduction Designed for chromatography by a combination of ion exclusion and partition/adsorption, the Shodex...
  • Page 3: Mobile Phase

    Operation Manual Shodex RSpak KC-811 and KC-811 6E Version 2020 Mobile Phase 1) An aqueous solution containing 0.1% phosphoric (H ) or perchloric acid (HClO ) is normally used as the mobile phase. Also sulfuric acid (H ) aqueous solution could be used. Concentration of the acid is around 1-6 mM.
  • Page 4 Operation Manual Shodex RSpak KC-811 and KC-811 6E Version 2020 Pre-treatment of Specimen 1) When the specimen is solid, dissolve it, using some of the degassed mobile phase. Note: Do not use any other solvent; otherwise, the solute sometimes settles in the mobile phase to plug the column.
  • Page 5 LC system, close each end with a stopper, and store it at controlled room temperature. 6) Filtrate the sample with a disposable filter (0 .45 µm) to prevent deterioration by adsorbing insoluble matters. 7) Contact Shodex website (www.shodex.de) or Shodex partners regarding product and analysis applications.
  • Page 6 User’s exclusive remedy and Showa Denko K.K.‘s exclusive liability for such claim are limited to the replacement of the Shodex Column in question. In no event is Showa Denko K.K. liable for any indirect, incidental or consequential damage arising out of in connection with the Shodex Column, whether or not such damage is allegedly based on breach of warranty, negligence or otherwise.

This manual is also suitable for:

Rspak kc-811 6eRspak kc-g 8bRspak kc-g 6bF6378030F6378033F6700010 ... Show all