Message
Cutting disc major imbalance
Too high battery current
Too high internal current
High charging power loss
High internal temperature
1691 - 002 - 14.01.2022
Cause
The product senses vibrations in the
blade disc.
The product has stopped because it has
operated on too high or thick grass or in
a too steep slope.
The contact between the charging plates
on the cutting deck and the contact
plates on the charging station is not
good.
Temporary electronic or firmware prob-
lem in the product.
The product has operated in too high
temperature, too high or thick grass or in
too steep slope.
Action
Make sure that the blades and screws
are not damaged or worn. Make sure that
all blades are correctly attached. Make
sure that there is only one blade attached
on each position in the blade disc.
Put the product on a level surface with
short grass and start the product. If the
problem stays, speak to your authorized
service center.
Polish the charging plates on the cutting
deck and the contact plates on the charg-
ing station.
Start the product. If the problem stays,
speak to your authorized service center.
Put the product in an area with protection
from the sun and wait. Put the product on
a level surface with short grass and start
the product. If the problem stays, speak
to your authorized service center.
Troubleshooting - 41
Need help?
Do you have a question about the CEORA Razor 43M and is the answer not in the manual?
Questions and answers