Setting a blanking area
When the antenna is installed at a close dis-
tance in front of the wheelhouse, the radar
should be set not to transmit within that area.
No echoes appear in the blanking areas.
1. Select "7. Dead Sector".
2. Press the [ENTER] key.
3. Operate the omnipad to enter starting point
of area (in figures).
4. Press the [ENTER] key.
5. Operate the omnipad to enter ending point
of area (in figures).
6. Press the [ENTER] key.
Figure 6-27 Blank areas where
transmission is suspended
This area can be turned on/off on the OTHER
MENU. For detail, see the description on page
18.
Note: This setting should be done after other
adjustments are finished.
Area of no
transmission

Magnetron heater voltage

Magnetron heater voltage is formed at the MD
Board of the antenna unit and preadjusted at
the factory for use with any length of signal
cable. Therefore no adjustment is required.
However, verify heater voltage by following
the procedure below.
1. Turn on the radar (if it is not already on)
and set it in stand-by.
2. Open the antenna housing (radome) cover.
Connect a multitester, set to 10 V DC range.
Model
Check Point
M1832
TP802 #4, #6 on
PTU Board
M1932
TP803 #4, #6 on
MD Board
M1942
TP803 #4, #6 on
MD Board
3. Close the antenna housing cover and tighten
the fixing bolts.
Rating
Adjustment
point
7.4~7.6V
R106
7.4~7.6V
VR801
7.5~7.7V
VR801
35