5 Connecting to power supply
12
The line break monitoring or alarm function defines the function of the
controller in case of failure.
To realize line break monitoring with the controllers VEGATOR 131 or
132, a supplementary electronics must be mounted in the connection
housing of the probe.
Cable colour blue - in conjunction with a VEGATOR 131, 132
controller
Fig. 6: Supplementary electronics for line break monitoring in conjunction with
VEGATOR 131, 132
1
Connection cable blue - in conjunction with the VEGATOR 131, 132, control-
lers
Mounting - Supplementary electronics
To mount the supplementary electronics, proceed as follows:
1. Open the terminal of the probe and attach the additional electron-
ics.
2. Connect the eyelet according to the following illustration.
Make sure that the eyelets have no contact to other metal parts.
3. Tighten the terminal.
1
Conductive probe EL 2 •