Lutron Electronics RT-606 Operation Manual

Lutron Electronics RT-606 Operation Manual

3 phase rotation tester

Advertisement

Quick Links

3 PHASE
ROTATION TESTER
Model : RT-606
OPERATION MANUAL
All manuals and user guides at all-guides.com
Your
purchase
ROTATION TESTER marks
a step forward for you into
the
field
of
measurement.
this TESTER is a complex
and delicate instrument,
its durable structure will
allow many years of use if
p r o p e r
o p e r a t i n g
techniques are developed.
Please read the following
instructions carefully and
always keep this manual
within easy reach.
of
this
precision
Although

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RT-606 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lutron Electronics RT-606

  • Page 1 All manuals and user guides at all-guides.com 3 PHASE ROTATION TESTER Model : RT-606 Your purchase this ROTATION TESTER marks a step forward for you into field precision measurement. Although this TESTER is a complex and delicate instrument, its durable structure will...
  • Page 2 All manuals and user guides at all-guides.com Caution Symbol Caution : * Do not touch the alligator clips by hand when make the measurement ! * Risk of electric shock ! Caution : * Do not apply the voltage > 660 ACV to the input terminal ! * Remove test alligator clips before make the fuse...
  • Page 3 All manuals and user guides at all-guides.com TABLE OF CONTENTS 1. SPECIFICATIONS............1 2. FRONT PANEL DESCRIPTION........2 2-1 Alligator clips............2 2-2 L1-L2-L3 indicator..........2 2-3 Clockwise indicator..........2 2-4 Counter clockwise indicator........2 3. OPERATION PROCEDURES.........3 4. MAINTENANCE............5 4-1 Replacement of Fuse...........5 4-2 Cleaning.............5 5.
  • Page 4 All manuals and user guides at all-guides.com 1. GENERAL SPECIFICATIONS Signal Input 100V AC up to 660 AC maximum, Voltage 3 min. limit for over 500V AC. Signal Current Approx. 7 mA per phase. Consumption Motor rotation tester : Signal Freq. Range 45 to 70 Hz.
  • Page 5 All manuals and user guides at all-guides.com 2. FRONT PANEL DESCRIPTION Fig. 1 2-1 Alligator clips 2-2 L1-L2-L3 indicator 2-3 Clockwise indicator 2-4 Counter clockwise indicator...
  • Page 6 All manuals and user guides at all-guides.com 3. OPERATION PROCEDURES Caution : * Do not touch the alligator clips by hand when make the measurement ! * Risk of electric shock ! Caution : * Do not apply the voltage >...
  • Page 7 All manuals and user guides at all-guides.com 4. MAINTENANCE Caution : * Remove test leads before make the fuse & battery replacement. ! * Cleaning - Only use the dry cloth to clean the plastic case ! 4-1 Replacement of Fuse 1)Fuse is used for the input protection of "...
  • Page 8 All manuals and user guides at all-guides.com 5. THE ADDRESS OF AFTER SERVICE CENTER 0703-RT606-IEC1010...

Table of Contents