• Regular refilling of salt into the brine tank is required for the system to operate properly; otherwise, it may cause the device to malfunction or be damaged. • Disconnect the device from the power supply if it is to be cleaned or moved. If the de- vice www.bestwater.de...
During rinsing. During the revitalisation pro- cess, the appliance regains its ion exchange capacity and can treat water again. This revitalisa- tion process allows you to use the water treatment system for a long time. www.bestwater.de...
Possibility of taking water from the network during re- generation regeneration behaviour Volumetrically delayed type up-flow down- flow Child lock Mass of the ion exchange container diameter / height 10 x 35 Contents of the ion exchange resins[L] Power connection 100-240 V/50-60 Hz Power usage [W] www.bestwater.de...
- Protect the unit from overfilling. There is an over- flow pipe on the side wall of the housing. The float valve regulates the refilling process of water and supplies the saline solution. Proper functioning ensures the correctness of the revitalisation process. www.bestwater.de...
Check this by blowing hard into the drain. Push the water softener bypass onto the screw connec- tion (control head). • Insert the safety bar. • Insert the plug to connect the water meter - drawing (A). www.bestwater.de...
The turbine should be at the outlet of the device. Before assembly, check that the tur- bine is rotating freely. To assemble the device, you must use the existing installation materi- als. If you have any problems or questions, contact a qualified company or authorized service company. www.bestwater.de...
Page 10
If necessary, the regeneration salt should be refilled so that the salt pool is availa- ble in sufficient quantity for the upcoming regeneration processes. Table 2 shows the average regeneration salt consumption. Attention: Please only use regeneration salt in tabs form. www.bestwater.de...
Page 11
6 m. • In the case of threaded connections without an additional seal, a suitable sealant e.g. Use PTFE Teflon tape. • Only open the main water connection when all work has been properly car- ried out www.bestwater.de...
You can edit the basic parameters in open menus. H. Set the time and water hardness and de- termine the time of regeneration. Switching between the parameters or changing the values is done by pressing the "up-down" buttons. The parameter selection and the confirmation of the changes are confirmed with "Enter". www.bestwater.de...
Page 13
Icon showing the locked keyboard If the symbol is displayed, the keyboard is locked. This function is activated after one mi- nute of inactivity. To activate the keyboard, one should press the buttons simulta- neously for min.5 seconds until the blockage symbol disappears. www.bestwater.de...
"closed". Then the valve on the water softener for sampling must be open and the water inlet can be opened slowly, step by step, to let water run into the system. The air escapes audibly through the inflowing water through the open valve on the water purifier. www.bestwater.de...
(water surface must not be visible). Salt may only be used in tablet form. CAUTION! Dissolved salt can cause irritation in contact with eyes and skin. In case of contact, rinse quickly with plenty of clear water. salt replenishment www.bestwater.de...
Pay attention to the integrity of the seals. Parts 12 and 14 must be loosened with a screwdriver. All parts should be rinsed under clear, warm water and then blown through. Then all parts are reassembled in reverse order. Drawing. F. Injector www.bestwater.de...
The longer the refill takes, the more salt can be dissolved. QUICK WASH - the system is in the 5th cycle - the brine bed (grounds container) is rinsed again and discharged through the main pipe into the sewage system. www.bestwater.de...
Check hose for blockage brine supply Leakage in the brine supply Change pipe hose Injector damaged Change Injector particles in the valve Check the valve and remove parti- cles and then check the valve in the various regeneration stages www.bestwater.de...
• The prerequisite for granting the guarantee is installation before the main line and systematic maintenance of the device. The guarantee does not apply to • inspection services; • device program change services; www.bestwater.de...
Page 21
• Incorrect installation, commissioning and use of the device; • The inspection is not carried out on time by a specialist; • Unauthorized repairs, changes and conversions by the buyer or third parties that do not comply with the instructions; mechanical damage to the device www.bestwater.de...
18. Installation sheet THE USER SHOULD MAKE SURE THE INSTALLER COMPLETES THE CORRESPONDING LINES IN THE TABLE. Device put into operation by: Pipe installation Company name:............Date: ......................….……………………… …………………………………………………………………… ... Name ..........………………………………………………………………………………… ………………………………...…............................….……………………………… …………………………………………………………………………..Tel.: ................electrical Installation Company name: Date: ..........
Need help?
Do you have a question about the BW 1500 and is the answer not in the manual?
Questions and answers