10 Reconnect the system to the electrical outlet, and turn on the system
and attached peripherals.
If the problem persists, the processor is faulty. See "Getting Help" on
page 162.
11 Turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
12 Remove the system-board assembly. See "Removing a System-Board
Assembly" on page 68.
13 Replace processor 1 with processor 2. See "Installing a Processor" on
page 73.
14 Repeat step 9 through step 11.
If you have tested both the processors and the problem persists, the
system board is faulty. See "Getting Help" on page 162.

IRQ Assignment Conflicts

Most PCI devices can share an IRQ with another device, but they cannot
use an IRQ simultaneously. To avoid this type of conflict, see the
documentation for each PCI device for specific IRQ requirements.
Table 4-1. Assignment Specific IRQ Requirements
IRQ
Assignment
Line
IRQ0
8254 timer
IRQ1
Keyboard controller
IRQ2
Cascade for IRQ9
IRQ3
Serial port
IRQ4
Serial port
IRQ5
Free
IRQ6
Free
IRQ7
USB controller
146
|
Troubleshooting Your System
IRQ
Assignment
Line
IRQ8
RTC
IRQ9
SCI
IRQ10
USB controller, NIC
IRQ11
VGA, USB controller
IRQ12
Mouse controller
IRQ13
Processor
IRQ14
Primary IDE controller
IRQ15
Secondary IDE controller