Summary of Contents for Pulsar MS 1012

  • Page 1 MS 1012 v.1.0 MS 13,8V/1A Buffer, switch mode power supply module. EN** Edition: 2 from 21.11.2016 Supersedes the edition: 1 from 18.09.2014...
  • Page 2: Table Of Contents

    MS1012 Features:  DC 13,8V/1A uninterruptible power supply  protections:  high efficiency 78%  SCP short-circuit protection  low voltage ripple  OLP overload protection  battery charging and maintenance control  OHP overheat protection  battery output full protection against short-circuit ...
  • Page 3: Description Of Components And Connectors

    MS1012 1.3. Description of components and connectors PSU module. Table 1. Elements of the PSU module pcb (fig. 2). Element no. Description potentiometer, DC adjustment fuse in the battery circuit Connectors: +BAT- DC supply output of the battery +AUX- DC supply output (+AUX= +U, -AUX=GND) LEDs –...
  • Page 4: Specifications

    MS1012 1.4 Specifications: - electrical parameters (tab.2) - mechanical parameters (tab.3) - operating parameters (tab.4) Electrical parameters (tab. 2). Mains supply 18V÷22V AC 30VA min. (e.g. AWT150) Current up to 1,45A max. Power frequency 50Hz Power Efficiency 11V÷ 13,8V DC – buffer operation Output voltage 10V÷...
  • Page 5: Installation

    MS1012 2. Installation. 2.1. Requirements. The buffer PSU module is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the II-nd environmental class, with normal relative humidity (RH=90% maximum, without condensing) and temperature from -10°C to +40°C.
  • Page 6: Operation And Use

    CAUTION! The power supply module unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl...