Delivery scope and unit configuration
 A
1
Filter housing with filter pump
2
Transition piece
 Fastens the filter pump to the filter cover
3
Reduction element
4
Ball joint with adjustable outlet ( 9 mm)
5
Telescopic extension, two-part, consisting of an external and an internal pipe
6
Stepped hose connection
7
O ring 12 × 4 mm for stepped hose connection (6)
8
Nozzles
Intended use
NPTP-O 1500-3500, referred to as "unit", may only be used as specified in the following:
 For pumping normal pond water for filters and water courses.
 Operate in accordance with instructions.
The following restrictions apply to the unit:
 Do not use in swimming ponds.
 Never use the unit with fluids other than water.
 Never run the unit without water.
 Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

Installation and connection

Use as a water course pump or filter pump
How to proceed:
 B
1. Screw the stepped hose adapter onto the transition piece of the pump and hand-tighten.
2. Actuate the engagement hooks on the filter housing.
3. Remove the strainer casing.
4. Place the unit in the pond on a horizontal, firm and sludge-free base and ensure that it is completely covered by wa-
ter.
5. Maximum installation depth: 2 m below the surface of the water.
Use as a fountain pump
How to proceed:
 C
1. Assembling the telescopic extension: Insert the internal pipe into the external pipe and secure with the retaining col-
lar.
2. Fit the telescopic extension onto the ball joint.
3. Ensure that the control valve on the telescopic extension and the outlet of the ball joint are aligned opposite each
other so that water can exit from the outlet of the ball joint.
– Ensure that the control valve on the telescopic extension and the outlet of the ball joint are aligned opposite each
other so that water can exit from the outlet of the ball joint.
– The adjustable outlet on the ball joint can be used for feeding a water course.
4. Insert and screw the desired nozzle into the telescopic extension.
5. Screw the ball joint onto the transition piece of the pump and hand-tighten.
– Vertically align the telescopic extension via the ball joint.
6. Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely cov-
ered with water.