Performance Data Sheet

SmartWater Filtration System-GE
This system has been tested and cert ed in lter model GE MWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as spec ed in NSF/ANSI Standards 42 and 53.* (Safety factors built in for unmetered usage)
Standard No. 42: Aesthetic effects
Substance
Reduction
Average Influent
Chlorine Taste
2.0 mg/L
& Odor
Nominal Particulate
7,833,333 pts/mL At least 10,000 particles/mL 99.7%
Class I, ≥0.5 to <1.0 μm
Standard No. 53: Health effects
Substance
Reduction
Average Influent
Cyst*
147,5000 cysts/L Minimum 50,000 cysts/L
Asbestos
47 MF/L
Atrazine
0.009 mg/L
Benzene
0.016 mg/L
Carbofuran
0.08 mg/L
Endrin
0.006 mg/L
Lead @ pH 6.5
0.152 mg/L
Lead @ pH 8.5
0.148 mg/L
Lindane
0.002 mg/L
Mercury @ pH 6.5
0.0058 mg/L
Mercury @ pH 8.5
0.0061 mg/L
P-Dichlorobenzene
0.222 mg/L
Tetrachloroethylene
0.015 mg/L
Toxaphene
0.015 mg/L
2, 4-D
0.218 mg/L
*Based on the use of Cryptosporidium parvum oocysts
Capacity 300 gallons (1,135 liters). Contaminant reduction determined by NSF testing.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.9 lpm)
Water Supply
Potable Water
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Operating Speci cations
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
Temperature: 33–100°F (0.6–38°C)
Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
trapped air.
expected to drop below 33°F (1°C). Do not install systems in areas where
ambient temperatures may go above 100ºF or below 40°F. Do not install
on a hot water supply.
Special Notices
Installation instructions are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s
instructions, including replacement of lter cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems cert ed for
cyst reduction may be used on disinfected water that may contain lterable cysts.
Tested and Cer
by NSF International against ANSI/NSF Standards 42 and 53 in model GE MWF for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical
– Chlorine Taste and Odor
GE
Appliances
Appliance Park
Louisville, KY 40225
geapplianceparts.com
NSF Specified Challenge
Average %
Concentration
Reduction
2.0mg/L ± 10%
97.5%
NSF Specified Challenge
Average %
Concentration
Reduction
99.99%
7
8
10
to 10
fibers/L; fibers
>99%
greater than 10 μm in length
0.009 mg/L ± 10%
94.5%
0.015 mg/L ± 10%
96.7%
0.08 mg/L ± 10%
98.7%
0.006 mg/L ± 10%
95.6%
0.15 mg/L ± 10%
99.3%
0.15 mg/L ± 10%
99.3%
0.002 mg/L ± 10%
99%
0.006 mg/L ± 10%
93.2%
0.006 mg/L ± 10%
93.2%
0.225 mg/L ± 10%
99.7%
0.015 mg/L ± 10%
96.6%
0.015 mg/L ± 10%
93.2%
0.210 mg/L ± 10%
99.5%
Mechanical Filtration
– Particulate Reduction, Class I
MWF Cartridge
®
Average Product
Max Permissible Product
Water Concentration
Water Concentration
0.05 mg/L
N/A
18,617 pts/mL
N/A
Average Product
Max Permissible Product
Water Concentration
Water Concentration
1 cyst/L
N/A
<1 MF/L
N/A
0.0005 mg/L
0.003 mg/L
0.0005 mg/L
0.005 mg/L
0.001 mg/L
0.04 mg/L
0.0003 mg/L
0.002 mg/L
0.001 mg/L
0.010 mg/L
0.001 mg/L
0.010 mg/L
0.00002 mg/L
0.0002 mg/L
0.0004 mg/L
0.002 mg/L
0.0004 mg/L
0.002 mg/L
0.005 mg/L
0.075 mg/L
0.0005 mg/L
0.005 mg/L
0.001 mg/L
0.003 mg/L
0.0009 mg/L
0.07 mg/L
Water Pressure
40–120 psi (2.8–8.2 bar)
Water Temperature
33ºF–100ºF (0.6ºC–38ºC)
The contaminants or other substances removed or reduced by this water
treatment system are not necessarily in your water.
Check for compliance with the applicable state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions,
actual performance may vary. Systems must be installed and operated in
accordance with manufacturer’s recommended procedures and guidelines.
Installation and use MUST comply with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPa), you should install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
controlling pressure due to thermal expansion must be installed.
Standard No. 53: Health Effects
Chemical Reduction
– Atrazine Reduction
– Endrin Reduction
– Benzene and Carbofuran Reduction
– 1,4 Dichlorobenzene and
2,4-D Reduction
NSF Reduction
NSF Test
Requirements
Report
≥50%
J-00077703
≥85%
J-00077704
NSF Reduction
NSF Test
Requirements
Report
≥99.95%
J-00077721
≥99%
J-00077707
N/A
J-00077708
N/A
J-00077717
N/A
J-00077718
N/A
J-00082185
N/A
J-00077722
N/A
J-00077723
N/A
J-00077726
N/A
J-00077727
N/A
J-00077728
N/A
J-00077729
N/A
J-00082184
N/A
J-00077730
N/A
J-00077705
– Lead and Lindane Reduction
– Mercury and Toxaphene Reduction
Mechanical Filtration
– Cyst and Asbestos Reduction