PREPARE FOR DUCTWORK
6
NOTE: Ductwork MUST be vented outside. DO
NOT vent into a wall, ceiling, crawlspace, attic or
any concealed space.
Determine the best route for ductwork; it can be
routed in a variety of ways depending on the
kitchen layout.
Typical duct arrangement countertop series.
Inside wall
"
"
3
1
x 10
cabinet
4
(8.2 cm x 25.4 cm)
Transition elbow
Up inside wall to roof
or overhang
Peninsula or island
Between floor joists
Optional duct arrangement under concrete slab.
NOTE: PVC sewer pipe type PSM 12454-B
Schedule 40 ASTM D1785.
Wall cap
6" (15 cm) Dia.
Metal Duct
12"
(30 cm)
Min.
6"
(15 cm)
Dia. PVC
coupling
6" (15 cm) Dia.
Pack tightly with gravel
PVC Sewer pipe
or sand completely
elbow
around pipe.
Installation Instructions
Outside wall
cabinet
Directly to outside
Peninsula
"
"
Transition
3
x 10
1
4
(8.2 cm x 25.4 cm)
Through cabinet toe space
5" to 6"
(12.7 cm to 15 cm)
6" (15 cm)
Metal transition
Dia. 90°
Metal Elbow
6" (15 cm)
Dia. Metal
duct
Concrete
slab
16"
6" (15 cm)
(40.6 cm)
Dia. PVC
Max.
Sewer Pipe
30' (9.14 m)-0" Max
6" (15 cm)
6" (15 cm) Dia.
PVC Sewer pipe
elbow

GAS CONNECTION

7
Make the gas
connection to the inlet
of the pressure
regulator on this
appliance with a 1/2"
pipe nipple with male
pipe thread. Use an
approved pipe joint
compound at pipe
connections.
Install a manual shut-off
valve in the gas line in
an easily accessible
location, as close to the
pipe stub as possible,
making allowances for
the ventilation ducting.
Be sure you know how
and where to shut off
the gas supply to the

cooktop.

NOTE:
Instead of using solid piping to connect to
pressure regulator, an approved flexible metal
appliance connector may be used between the
pipe stub and shut-off valve and the pressure
regulator, if local codes permit.
Appropriate flare union adapters are required at
elbow
each end of the flexible connector.
Turn on the gas; check for leaks using a liquid
leak detector at all joints in the system.
CAUTION: DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.
IMPORTANT—Disconnect the cooktop and the
individual shut-off valve from the gas supply
piping system during any pressure testing of that
system at test pressures greater than
Isolate the cooktop from the gas supply piping
system by closing the individual manual shut-off
valve to the cooktop during any pressure testing
of the gas supply piping system at test pressures
equal to or less than
6"
(15 cm)
Dia.
PVC
coupling
Dia. PVC
Sewer
pipe
22
Gas appliance
pressure
regulator
1/2" Threaded
pipe nipple
Shut-off valve
Pipe stub
1
PSIG.
2
1
PSIG.