Part 2 - USE AND MAINTENANCE INSTRUCTIONS

3.1 - Synthetic filters

1 - This filter cannot be washed and should
be replaced every two months. If the filter
is provid ed with a saturation indicator,
replace when the violet color of the dots
which are visible from the outside is
spread over the whole surface of the filter.
2 - Replacement:
a) Remove the ducting grill, referring to
paragraph 3.1.3. on installation.
b) After having taken off the ducting grill,
remove the filter stops (1). Replace the
grease filter (2) (fig. 6).
c) Close the ducting grill up again.

3.2 - Charcoal filters

1 - Functioning
In the recycling mode the charcoal
filters absorb smell and odours.
The charcoal filter cannot be
washed or regenerated and should
be replaced every 2 months or
more frequently if the hood is used
consistently.
2 - Replacement:
a) Remove the ducting grill, referring to paragraph 3.1.3. on installation.
b) Replace the active charcoal filter (fig. 7).

3.3 - Lighting

1 - This is provided by two 40 W lamps . If the lamps do not work, open the suction grille
and check that they are properly fitted. If the lamps have burned out they must be
replaced using others of equivalent voltage
and power.
2 - Replacement:
a) 40 W lamp (fig.8), unscrew the burned out
lamp and fit the new one.
3 - Replace the suction grille.