RD-G2+ DIGITAL REPEATER

SAFETY PRECAUTIONS

- Always disconnect the power supply before installing or making modifications to the device.
- The fitting and handling of this device must be carried out by authorised personnel.
- The wiring must run at list 40 cm. de cualquier otra instalación.
- Install the RD-G2+ module in a dry protected location free from risk of dripping or splashing water.
- Install the
RD-G2+
module "
-
Avoid locations that are humid, dusty or near heat sources.
-
Ensure that the air vents are free from obstruction so that air can circulate freely.
-
To prevent damage, the RD-G2 module must be firmly secured in place.
C ARACTERÍSTIC
H
-
RD-G2+ digital repeater module with simplified wiring (non-polarised 2-wire bus
-
RD-G2+ digital repeater module for the G2+ system that allows the following operating modes
w Amplifi
er
mode:
-Allows to increase the monitor bus distance, 1 RD-G2+ module "amplifier mode" and 1 RD-G2+ module "power
mode" with its power supply unit FA-G2+ are required (see page 4 and 26).
-Allows to increase the bus distance in a "power mode" or "block mode" system when it is more than 300 m
between the
door panel
Important: Up to 4 RD-G2+ modules in amplifier mode.
w Power mode:
-Allows 32 additional monitors (max. 4 RD-G2+ and up to 128 elements).
-Allows risers/verticals installation ( a . 32 risers
installation.
-Up to 4 door panels.
-Door panels with EL632-G2 + SE video module with 'V04' or later for compatibility with this operating mode.
w Block mode:
-Allows an installation with up to 4 general door panels and up to 32 buildings with interior door panels.
-Up to 4 door panels e
-Up to 4 generals coded panels.
-Up to 32 i terior buildings up to 4 interior door panels per interior building
n
-RD-G2+ module "block mode" with its FA-G2+ power supply per inner building.
-Door panels with EL632-G2 + SE video module with 'V04' or later for compatibility with this operating mode.
- FA-G2+ power supply unit is required for each RD-G2+ module in "power mode" and "block mode".
- It is necessary to configure the operating mode.
-
DIP switches (operating mode, building address number "
-
Power supply status
Led.
RAP-2150 (GOLMAR) CABLE CHARACTERÍSTICS
CONSTRUCTION CHARACTERISTICS
Flexible 1mm twisted pair polished copper conductor
2
Wiring
ELECTRICAL CHARACTERISTICS
Electrical resistance of the conductor at 20°C
Capacity between conductors
Characteristic impedance
power mode
" and "
block mode
+
S
and the first RD-G2+ "amplifier mode" (see page 5, 9, 29 and 35).
m x
p r interior
building
.
(
" together with its FA-G2+ power supply
/vertical
s
, up to 32 monitores per riser and up to128 monitors in
,
).
,
block mode
" and end of line
VALUES
Class V
15 V/m
VALUES
19 5
.
/Km
45pf/m 10%
100
10%
.
).
:
).
3