42
36
Side View
GE Appliances
DBLR333EE – GE
5.8 Cu. Ft. Extra-Large Capacity Electric Dryer
®
Dryer Dimensions (in inches)
23-1/2
25-3/4
*24-1/2" from the edge of the side panel to the front.
25-1/2" from the front edge of endcaps.
25-1/2*
4-3/4
36
Side View
Exhaust Options:
Electric – 4-way via rear, right, left and bottom.
Circuit Requirements:
Electric – An individual, properly-grounded branch circuit, protected by a
RCA Washer/Dryers LC4 QSart
30-amp circuit breaker or a time-delay fuse, is required.
Electric Dryer Rating:
240V, 5600W, 24A, 60 Hz
208V, 4400W, 22A, 60 Hz
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible when
dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed with
your dryer.
For answers to your Monogram,
GE
appliance questions, visit our website at
®
Listed by
Underwriters
GEAppliances.com or call
R
Laboratories
GE Answer Center
Specification Created 2/04
370278
Rear View
27
42
11-3/4
2
5-1/2
2-1/2
Rear View
GE Profile
or
®
™
service, 800.626.2000.
®
GE Dryer Vent
GE Dryer Vent
Dryer Exhausting Information – Use Metal Duct Only
Vertical and Horizontal Ducting
Best Performance
Maximum Length of 4" Dia.
Rigid Metal Duct
A
A
Exhaust Hood Type
A
4
Number
B
4
B
of
A
Domestic
90°
4" Opening
2-1/2
Dryer Models
Turns
Opening
2-1/2
0
90 ft.
1
60 ft.
7.0, 6.0 and 5.8
2
45 ft.
Capacity Models
3
35 ft.
all Electric Dryers
4
25 ft.
0
90 ft.
7.0, 6.0 and 5.8
1
60 ft.
Capacity Models
2
45 ft.
all Electric Dryers
3
35 ft.
0
90 ft.
7.0, 6.0 and 5.8.0
1
60 ft.
Capacity Models
2
45 ft.
all Gas Dryers
3
35 ft.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a
label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52" .
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of
60 sq. in. of open area equally distributed. If this closet contains both a washer and a
dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" both sides
3" rear
Maximum Length of 4" Dia.
Flexible Metal Duct
Exhaust Hood Type
B
A
B
2-1/2"
4" Opening
2-1/2"
Opening
127 ft.
75 ft.
52 ft.
117 ft.
65 ft.
42 ft.
107 ft.
55 ft.
32 ft.
97 ft.
45 ft.
22 ft.
87 ft.
35 ft.
12 ft.
60 ft.
55 ft.
45 ft.
45 ft.
40 ft.
30 ft.
35 ft.
30 ft.
20 ft.
25 ft.
20 ft.
15 ft.
60 ft.
55 ft.
45 ft.
45 ft.
40 ft.
30 ft.
35 ft.
30 ft.
20 ft.
25 ft.
20 ft.
15 ft.