Zenith XBV243 Service Manual page 61

Table of Contents

Advertisement

E.
In PB mode Tape Presence
not sensed.
Is the Pinch Roller attached
to the Capstan Motor Shaft?
YES
Does the T/Up
Reel turn?
YES
Does the Capstan Motor turn?
YES
Does the Drum
Motor turn?
YES
Are there DPG,
DFG Pulses?
YES
Are the T/Up Supply
Reel Sensors ok?
YES
Check Servo, Syscon.
Does the Capstan Motor turn?
VR168 - 923-03485
All manuals and user guides at all-guides.com
MECHANISM - VCR
NO
Check Alignment positions
(page 4-14)
NO
Is the Belt ok?
YES
Check the clutch and
the Idler Assembly.
NO
Is the Voltage supplied to the
Capstan Motor Vcc1,Vcc2 each?
YES
Is the terminal voltage of Capstan
Motor supplied more than 4V?
YES
Replace the
Capstan Motor.
NO
Is the Vcc voltage of the
Drum Motor normal?
YES
Is the terminal voltage of the
Drum Motor more than 2.3V?
YES
Replace the
Drum Motor.
4-25
NO
Replace the Belt.
NO
Check Syscon,
Circuit.
NO
Check Syscon,
Circuit.
NO
Check Servo,
Power.
D35E COMBO - SERVICING