Battery connection

Connect the 12VDC or 24VDC power line, where present, directly to the battery, following the instructions
below.
Connect the refrigerator to the battery using the special cables provided
Respect the polarity
Check that the battery's nominal voltage corresponds to the refrigerator's nominal data shown on the
product label. Provide a 25 A thermal-magnetic breaker type remote voltage switch. The remote switch
must disconnect both the poles of the battery. If the power cables to the battery are extended, use
appropriate connections that are able to support the minimum current of 20 Amperes. Use wires with a
minimum section and a maximum length as given in the table.
12 V cut-out V
12 V cut-out V
10.4
In the event that the appliance's plug and the socket are not compatible,
replace the plug with a suitable one.
This operation must be done by a suitably qualified person who must
ensure that the cable section of the plug is appropriate to the power
absorbed by the appliance.
Do not interconnect any other type of appliance to the refrigerator.
2
Sec.[mm
] Max.lin.length 12V [m]
2.5
4
6
10
STANDARD BATTERY PROTECTION SETTINGS
12 V cut-in V
12 V cut-in V
11.7
2.5
4
6
10
24 V cut-out V
24 V cut-out V
22.8
48
Max.lin.length 24V [m]
5
8
12
20
24 V cut-in V
12 V cut-in V
24.2