Setup & Programming The Operating Parameters In The Telguard; Command Key Sequences For Pots Programming - Telular TELGUARD DIGITAL TG-1 Installation And Operating Instructions Manual

Residential primary cellular alarm communicator, cellular alarm transmission system using gsm digital cellular technology
Table of Contents

Advertisement

The first alarm is for registration of the Telguard unit. The first alarm will NOT be transmitted
to the central station.
NOTE: SPECIAL LED INDICATIONS DURING ACTIVATION
IF THE TELGUARD FAILS THE REGISTRATION PROCESS IT WILL BE DISPLAYED ON THE LEDS.
1. IF LED 4 AND LED 1 ARE FLASHING, THE TELGUARD SERIAL NUMBER IS NOT IN THE DATABASE AT THE
TELULAR COMMUNICATION CENTER, CALL TECHNICAL SUPPORT TO VERIFY PROPER LINE RANGE.
2. IF ALL OF THE LEDS ARE FLASHING, THE REGISTRATION MESSAGE WAS NOT RECEIVED AT THE
TELULAR COMMUNICATION CENTER. RETRY TRANSMITTING REGISTRATION MESSAGE. IF TELGUARD
FAILS A SECOND TIME TO REGISTER, CHECK SIGNAL STRENGTH. IF SIGNAL STRENGTH IS OK, THEN
CALL TECHNICAL SUPPORT.
ON EITHER INDICATION OF FAILED REGISTRATION, THE UNIT MUST BE RESET BY PUTTING THE J10 (RSSI
JUMPER) IN. THE REGISTRATION MESSAGE MUST BE RESENT OR THE TELGUARD WILL TRANSMIT ALL
SIGNALS THROUGH THE TELCO CONNECTION.
SYSTEM STATUS LEDS
ALL LEDS FLASHING
LED 4 & LED 1 FLASHING
LED 1 ON
SYSTEM TROUBLE CONDITION, STC (LED #2)
STATUS LED #2
1 FLASH
2 FLASH
3 FLASH
4 FLASH
5 FLASH
6 FLASH
5.3.1 Setup & Programming the Operating Parameters in the Telguard
When the Telguard is received from the factory and is powered up for the first time, it is immediately ready for
registration, provided the default settings are what you want. The STC LED will flash to indicate any failure
conditions. The Mode LED will be on and the STC relay will be tripped. If changes are required to the default
settings, the Telguard can be programmed using a line-mans butt-set connected to T & R Test Points or a
POTS phone connected to J7 (where the C/C is normally connected).

5.3.1.1 Command Key Sequences for Pots Programming

Key Sequence
# *
*
TO PROGRAM THE TELGUARD
A. Put the line-mans butt-set in talk mode or pick up the POTS phone,
B. Connect power to the Telguard, when ready for programming you will hear 2 beeps
C. Press #, *, this will put the Telguard into a Master Access programming mode, 2 beeps.
D. Enter changes required
The syntax for programming a specific memory location is as follows:
MEMORY LOCATION (3-digits), will respond with 2 beeps, then VALUE, will respond with 2
beeps. At this point, the changes have been saved.
E. Then press *, you will hear 2 beeps then hang up. This saves the change and exits the
programming mode.
56034002 1/9/2006
REGISTRATION INDICATIONS
FAILED REGISTRATION – SIGNAL TOO WEAK
REGISTRATION ERROR – CALL TECHNICAL SUPPORT
REGISTRATION SUCCESSFUL
INDICATION
AC LOW/MISSING
LBC LOW BATTERY AND/OR BATTERY CHARGER FAIL
N/A
NSC NO SERVICE
RFC RADIO FAILURE
DTF DIAL TONE FAIL
Description
Enters the programming Mode
Exits programming and stores changes
9
© 2006 Telular Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Telguard digital tg1g0001

Table of Contents