Bioer NPA-96 Operation Manual

Nucleic acid purification system

Advertisement

Quick Links

Nucleic Acid Purification System
NPA-96
Operation Manual
Hangzhou Bioer Technology Co.,Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NPA-96 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bioer NPA-96

  • Page 1 Nucleic Acid Purification System NPA-96 Operation Manual Hangzhou Bioer Technology Co.,Ltd.
  • Page 2 This document contains proprietary information protected by copyright. All rights reserved. Without prior written consent from Hangzhou Bioer Technology Co., Ltd., any part of the manual shall not be duplicated, reproduced or translated into any other languages.
  • Page 3 Bioer Company is not responsible for any consequences caused by users' failure to comply with the following requirements.
  • Page 4 Hangzhou Bioer Technology Co., Ltd. by the user. The freight incurred for products beyond warranty period shall be borne by the user. Hangzhou Bioer Technology Co., Ltd. will bear the freight incurred by returning instrument. For products within the warranty period, the round-trip freight ―...
  • Page 5 Nucleic Acid Purification System will be borne by Bioer. (For domestic users only) For maintenance out of warranty period, Hangzhou Bioer Technology Co., Ltd. will charge for certain maintenance cost. b) Warranty scope The abovementioned warranty does not apply to damages incurred by improper use and maintenance, using under unqualified conditions, unauthorized maintenance or modification.
  • Page 6: Table Of Contents

    Contents Chapter I Introduction........................1 Instrument Features ........................1 Instrument Use ..........................1 Chapter II Features ..........................2 1. Normal Working Conditions ......................2 2. Transportation and Storage Conditions ..................2 Basic Parameters ..........................2 Basic performance .......................... 3 Software functions .......................... 3 Chapter III Preparatory Work ......................
  • Page 7: Chapter I Introduction

    This method can not only shorten the time of conventional purification process by nearly half, but also effectively prevent the aerosol pollution caused by the fluctuation of magnetic rod. This product is used for the extraction and purification of nucleic acid from clinical samples. Hangzhou Bioer Technology,.Ltd...
  • Page 8: Chapter Ii Features

    NPA-96 Parameters Sample size 96 pcs/time Magnetic rod (fixed) 96 pcs 10~1000μl Sample range Magnetic bead collection ≥99% efficiency Most suitable size of magnetic 0.2~1.0μm beads Overall dimensions mm 907× 495× 571(L× W× H) Net weight 81.5Kg Hangzhou Bioer Technology,.Ltd...
  • Page 9: Basic Performance

     Software upgrade function, to update the main modules of the program and control parameters The above software features are for reference only, and changes to the software Caution: features are not subject to notice. Hangzhou Bioer Technology,.Ltd...
  • Page 10: Chapter Iii Preparatory Work

    Structure Diagram ⑵ ⑴ ⑶ ⑴ ⑹ ⑷ ⑸ ⑼ ⑻ ⑺ Back view of full automatic nucleic acid extraction and purification system ⑽⑾ ⑿ Hangzhou Bioer Technology,.Ltd...
  • Page 11: Check Before Startup

    The positions of transport lock blocks 1 and 2 are shown in the following figure: Lock block 1 Lock block 2 Please use the M4 inner hexagon wrench to remove the screw in the center of the lock block. Hangzhou Bioer Technology,.Ltd...
  • Page 12: Startup

    "ok" will pop up the dialog box of warning before starting self-check. If the transport lock blocks (lock block 1 and lock block 2) are not removed, please remove the transport lock blocks first and proceed with the procedure. Hangzhou Bioer Technology,.Ltd...
  • Page 13: Consumable Setting

    If the instrument is in operation state, click the icon of the center to further check the detailed operation information. The following are the idle and runtime main interfaces, respectively. Hangzhou Bioer Technology,.Ltd...
  • Page 14 The middle operation status button and status information are displayed only when the equipment is in operation. Press the operation state button to enter the operation state interface to view the detailed information of the operation state. Hangzhou Bioer Technology,.Ltd...
  • Page 15 New: After creating the default file, go to the file editing interface to edit the newly created file Edit: Go to the File Editing Interface to edit the currently selected file Run: Run the currently selected file The following image shows the[History Browsing] interface Hangzhou Bioer Technology,.Ltd...
  • Page 16 The following figure shows the [U disk file] browsing interface, which can only be displayed when the U disk is inserted. If the U disk is not inserted and it will be prompted for failure to detect the U disk. Hangzhou Bioer Technology,.Ltd...
  • Page 17 Press the left and right arrows to switch the display information, and the middle and lower part displays all the procedure information of the program, including hole location, step name, waiting time, mixing time, magnetic suction time, volume, mixing mode and adsorption mode. Below are function buttons, including Hangzhou Bioer Technology,.Ltd...
  • Page 18 After setting, click [OK] to return to the file editing interface. If [Cancel] is pressed, the change is waived. If you click the currently selected step area, you will enter the step parameter setting interface, as shown in the following figure: Hangzhou Bioer Technology,.Ltd...
  • Page 19 It allows you to select the appropriate name in a pre-set list of step names to describe the action that the step performs. See step name management section for how to add or remove preset step names (as above). Hangzhou Bioer Technology,.Ltd...
  • Page 20 Click the edit box below the mixing mode, and the right keyboard area will display the alternative blending mode. This is shown below. The 3 mixed steps can be used for cycling, allowing the number of cycles to be set, with valid values ranging from 1 to 100. Hangzhou Bioer Technology,.Ltd...
  • Page 21 RPM. The allowable value range is 100~2000. Input 0 indicates the suspension of this step. The other parameters are defined in the same way as when the sheath is used. Hangzhou Bioer Technology,.Ltd...
  • Page 22 Click the save icon to display the file [File Save] interface, as shown in the figure below. Hangzhou Bioer Technology,.Ltd...
  • Page 23 The bottom is the function button, including: reset, pause and stop. After the experiment is suspended, the function button below will Reset and Pause and be replaced by Continue Reset: pause the experiment and raise the TIP head Hangzhou Bioer Technology,.Ltd...
  • Page 24 Display time unit: minutes. e. UV light setting When the device is idle, click the UV lamp setting on the main interface to enter the UV lamp setting interface, as shown in the figure below. Hangzhou Bioer Technology,.Ltd...
  • Page 25 Click on the system settings to enter the [System Settings ] interface in the operation main interface The 6 buttons in the middle correspond to 6 Settings. Click the button in the upper left corner to return to Hangzhou Bioer Technology,.Ltd...
  • Page 26 OK or Cancel button to return to the system setting interface (as below). i. Parameter Setting Click the parameter setting button to display the interface of [Please Enter Password], as shown in the figure below. Hangzhou Bioer Technology,.Ltd...
  • Page 27 New: Add a new step name tag for English and Numbers only and slip line for up to 12 characters, preferably no more than 8 characters Delete: Delete the selected custom name label. The default name is not removable Clear: Remove all custom name tags, leaving only the default name tags Hangzhou Bioer Technology,.Ltd...
  • Page 28 Click [OK] button to start the upgrade process, and click [Cancel] button to return to the system setting interface. Please follow the System Upgrade Instruction for the specific operation process. Hangzhou Bioer Technology,.Ltd...
  • Page 29: Chapter V Fault Analysis And Troubleshooting

    The screen keys don't Contact with the supplier Touch screen is damaged work or manufacturer The screen prompts Display communication line fault between Contact with the supplier communication main control board and drive control board or manufacturer failures Hangzhou Bioer Technology,.Ltd...
  • Page 30 Please contact After device Error code:0x000100A3, reference position supplier self-check, the of sheathed motor not found manufacturer after screen displays Error code:0x000100A4, sheath motor reset taking pictures error code failed Error code:0x00020002, lysis oscillator temperature sensor fault Hangzhou Bioer Technology,.Ltd...
  • Page 31 Before the instrument is transported over a long distance, the moving platform must be mechanically locked in order to prevent damage to the instrument during transportation. The locking method is as follows: 1. Start the instrument and click [Setup] on the main interface to enter the interface of [System Setup]. Hangzhou Bioer Technology,.Ltd...
  • Page 32 If it cannot be installed, please go through the negative find tuning button of -1 or -5 to adjust the platform position. 7. After installation of transportation lock block 1, click the exit button to close the application and the instrument. Hangzhou Bioer Technology,.Ltd...
  • Page 33 During the warranty period, it is strictly prohibited for the user to open the Caution: instrument shell for self-inspection. In case of any fault in the table that needs to be opened for inspection, the user shall contact the supplier or manufacturer in a timely manner. Hangzhou Bioer Technology,.Ltd...
  • Page 34 Appendix 1: Wiring Diagram of Automatic Nucleic Acid Extraction and Purification Instrument (This drawing is for reference only, subject to change without prior notice) 接线图一 Wiring Diagram I...
  • Page 35 接线图二 Wiring Diagram II...
  • Page 36 接线图三 Wiring Diagram...
  • Page 37 Hangzhou Bioer Technology Co., Ltd. Hangzhou Bioer Technology Co., Ltd. Add: No.1192Binan Road, Hi-New (Binjiang) District, Hangzhou. P.C.: 310053 Tel:+86-571-85800535,87774558 Fax:+86-571-85800537,87774559 E-mail: instrument@bioer.com.cn www.bioer.com.cn...