BACKUP / RESTORE ISF SETTING
VLP43+ and VLP43++ models - If the customer has calibrated the ISF (ADV) video settings, the settings data
can be backed up on a USB memory device. If the settings are lost due to a Reset or Initialization procedure,
PWB-MAIN replacement or other reasons, the settings data can be restored.
Backup ISF Settings.
1. Insert a empty USB memory device into the USB slot.
2. Press the <MENU> button on the remote control. The Customer Menu will appear.
3. Press the <2-4-5-7> buttons. The Service Menu will appear.
4. Press the <0> button. The Data Selection Menu will appear. See below.
5. Use the <
> buttons to select "BACKUP AND RESTORE ISF SETTING" and press <ENTER>.
6 Use the <
> buttons to toggle to "Backup ISF Settings to USB" (Default).
7. While "Backup ISF Settings to USB" is displayed, press <ENTER>. The screen will flash the
message "Backup completed."
8. Remove the USB memory device and store it in a safe place.
9. Press <MENU> to exit.
Restore ISF Settings.
1. Insert the USB memory device with the backup data into the USB slot.
2. Press the <MENU> button on the remote control. The Customer Menu will appear.
3. Press the <2-4-5-7> buttons. The Service Menu will appear.
4. Press the <0> button. The Data Selection Menu will appear. See above.
5. Use the <
> buttons to select "BACKUP AND RESTORE ISF SETTING" and press <ENTER>.
6. Use the <
> buttons to toggle to "Restore ISF Settings From USB."
WARNING: DO NOT press <ENTER> while "Backup ISF Settings to USB" is displayed. The data on the
USB will be overwritten and lost.
7. While "Restore ISF Settings From USB" is displayed, press <ENTER>. The screen will flash the
message "Restore completed." The TV will then turn off.
8. Remove the USB memory device before turning the TV back on.
SOUND PROJECTOR TRANSDUCER TEST
BACKUP AND RESTORE ISF SETTINGS
RED ONLY AND GREEN ONLY
SET SCREEN SIZE
BACKUP / RESTORE ISF SETTING MENU
Backup ISF Settings to USB
BACKUP / RESTORE ISF SETTING MENU
Backup ISF Settings to USB
Backup completed
BACKUP / RESTORE ISF SETTING MENU
Backup ISF Settings to USB
BACKUP / RESTORE ISF SETTING MENU
Restore ISF Settings from USB
Restore completed