Sony STR-DA3300ES Operating Instructions Manual page 100

Multi channel av receiver
Hide thumbs Also See for STR-DA3300ES:
Table of Contents

Advertisement

Performing auto calibration
For details on the auto calibration, see "9:
Calibrating the appropriate speaker settings
automatically (Auto Calibration)" (page 43).
Refer to "Before you perform the auto
calibration" (page 43) before performing the
auto calibration.
To operate on the receiver
1
Press SHIFT, then press MENU to
switch from "GUI MODE" to "DISPLAY
MODE."
2
Press AMP.
Receiver operation is enabled.
3
Press MENU.
"Auto Calibration" is displayed.
4
Press
.
5
Press V/v repeatedly to select "AUTO
CAL START?," then press
the measurement.
Measurement starts in five seconds. A
count down is displayed.
Note
While the time is counting down, stand away
from the measurement area to avoid
measurement error.
6
Measurement starts.
The measurement process will take
approximately 30 seconds. Wait until the
measurement process completes.
To cancel auto calibration, change the volume,
activate the MUTING function, switch
functions, change the setting of the
SPEAKERS switch of the receiver, or connect
headphones.
Note
You cannot measure the speaker height of the
surround speakers and the surround back speakers.
Set this value from "SP POSI." settings in the
Speaker settings menu.
100
GB
Tips
• Operations other than turning the receiver on or off
are deactivated during auto calibration.
• When special speakers, such as dipole speakers are
used, the measurements may not be performed
correctly or auto calibration cannot be performed.
To confirm/save auto calibration
when GUI function is turned off
1
Confirm the measurement result.
When the measurement ends, a beep
sounds and the measurement result appears
on the display.
Measurement
result
When the
measurement
process
completes
properly
When the
measurement
process fails
to start
2
Press V/v repeatedly to select the item,
then press
The measurement results are saved.
Item
RETRY
SAVE EXIT
WRN CHECK
PHASE INFO
DIST.INFO
LEVEL INFO
Display
Explanation
COMPLETE Proceed to step
2.
ERROR
See "Message
CODE 3x
list after auto
calibration
measurement"
(page 48).
.
Explanation
Re-performs the auto
calibration.
Saves the measurement
results and exits the setting
process.
Displays a warning
concerning the measurement
results. See "When you select
"WRN CHECK"" (page 48).
Displays the phase of each
speaker (in phase/out of
phase). See "When you select
"PHASE INFO"".
Displays the measurement
result for speaker distance.
Displays the measurement
result for speaker level.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents