Proper installation
Do not install the machine in an area where a danger of explosion
or of freezing temperatures may be present.
Be careful when installing the dishwasher. Wear protective
gloves to avoid injury on any sharp metal components.
To ensure the stability of undercounter dishwashers, these units
may only be installed beneath a continuous countertop that is bolted
to adjacent cabinetry.
In order to reduce the risk of damage from condensation, the cab-
inetry in the area around the dishwasher should be designed for
commercial use.
Delicate cabinetry can be protected using the damp protection set,
which is available as an optional accessory.
The vapor barrier film needs to be adhered to the underside of the
countertop where the dishwasher door is opened.
The door springs must be evenly adjusted on both sides. They are
correctly adjusted when the door remains stationary when left half
open (approx. 45° opening angle). It is also important that the door
cannot fall open.
The machine must only be operated with properly adjusted door
springs.
If the door cannot be adjusted properly, contact the Miele Customer
Service.
The maximum weight of the front panel that can be aligned with the
factory-installed door springs is 22-26.5 lb (10–12 kg) (depending on
model).
Technical safety
This dishwasher should be installed, commissioned, repaired, and
maintained by Miele Service, a dealer, or a suitably qualified special-
ist. Unauthorized installation, maintenance, and repairs can cause
considerable danger for the user.