● Plasmacluster ions will be generated in all operation modes.
● When operation is stopped by pressing the POWER OFF button on the main unit or
the remote controller, the last operation mode will be memorized. (Memory Function)
● The settings of the timers, Plasmacluster Ions Clean mode and Clothes Deodorizing
mode will not be memorized.
● When the unit is power off or unplug from the outlet, the memory will be erased.
Start/Stop foot warming operation
Hot air is projected downwards to warm your feet.
Main unit
(orange mark)
w
You cannot start the
foot warming operation with
the remote controller.
Main unit
USEFUL FUNCTIONS
Auto Fan Speed mode
Main unit/Remote controller
Pip
The fan speed will be automatically switched to maintain the room temperature at 22°C.
(After starting the operation, the fan speed will increase from Level 1 to Level 6 within 2 minutes regardless of
the room temperature.)
Quick warming operation: when the room temperature is below 15°C, the unit will operate at a fan speed higher
than Level 6 for approximately 20 minutes.
(FAN SPEED indicator: all indicators will go off from left to right in order)
● When the humidity is above 65%, the hot fan operation will start automatically to raise the room temperature up
to 20°C.
● Due to the variation of room size, it may be impossible to raise the room temperature to 22°C.
● When the room temperature is 26°C or higher, the operation will stop (AUTO FAN SPEED indicator: on; FAN
SPEED indicator: off), and when the room temperature is 21°C or lower, the operation will start again.
(When the humidity is above 65% and room temperature is 24°C or higher, the operation will stop, and when the
room temperature is 19°C or lower, the operation will start again.)
The unit will start operating at the most suitable fan speed depending
on room temperature and humidity.
(The operation will start at fan speed "3" for approximately 2 minutes
regardless of the room temperature.)
IG-HH1A_0607.indd
10
● The FAN SPEED indicator, the FOOT WARMING indicator, and the
HOT FAN indicator will turn on.
Pip
(The FAN SPEED indicator will turn on in orange during foot warming
operation)
Operation
panel
● The settings of foot warming operation are as follows.
Fan Speed: Level 3; Vertical Swing: 10° upward - 40° downward;
Horizontal Swing: 30°
● With the Automatic Switch-off function, the foot warming operation will
stop automatically after 8 hours of continuous operation.
Remote controller
Pip
Display
Operation panel
Display panel
Display panel
● When switching off foot warming operation:
All indicators go off
1
Cool fan operation runs for 30 seconds to cool
2
down the inner unit before operation stops.
● Do not unplug the unit before the operation stops.
To cancel the mode, press the
AUTO FAN SPEED button
again or the FAN SPEED
button.
Temperature (standard)
24 25 26 27 28 29 30 31 32 33 34 35 →
Humidity
(High)
Level
(Medium)
1
(Low)
E-10
Level
Level
Level
Level
Level
2
3
4
5
6
2017/06/13