CHAPTER 3 EXPOSURE SYSTEM
2.
Operations
a.
Turning On/Off the Scanning Lamp
The DC controller PCB and the composite power supply exchange signals in serial communi-
cation to control the scanning lamp. According to the scanner lamp active voltage signal, the mi-
croprocessor (Q900) on the composite power supply PCB controls the intensity adjustment signal
(PWM_1KHz) and the lamp activation signal (LAMP_ON) to turn on/off the scanning lamp
(LA1).
When LAMP_ON is '0',
The phase control circuit turns on.
The arcing circuit turns on.
The scanning lamp turns on.
When LAMP_ON is '1',
The phase control circuit turns off.
The arcing circuit turns off.
The scanning lamp turns off.
3-10
COPYRIGHT © 1999 CANON INC.