Nominal Data; Data Acc. To Erp Directive; Technical Description; Mounting Data - ebm-papst W4E400-CP02-31 Operating Instructions Manual

Hide thumbs Also See for W4E400-CP02-31:
Table of Contents

Advertisement

W4E400-CP02-31

3.2 Nominal data

Motor
M4E074-EI
Phase
1~
Nominal voltage in VAC
230
Frequency in Hz
50
Type of data definition
fa
Valid for approval /
CE
standard
-1
Speed in min
1430
Power input in W
160
Current draw in A
0.73
Motor capacitor in µF
6
Capacitor voltage in VDB 400
Max. back pressure in Pa 150
Min. ambient
-25
temperature in °C
Max. ambient
40
temperature in °C
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations

3.3 Data acc. to ErP Directive

Installation category
Efficiency category
Variable speed drive integrated
Specific ratio
*
*
Specific ratio = 1 + p
/ 100 000
sf
Overall efficiency η
e
Efficiency grade N
Power input P
in kW
e
Air flow q
in m³/h
v
Pressure increase total p
in Pa
sf
Speed n in min
-1
Data established at point of optimum efficiency

3.4 Technical description

Mass
8.01 kg
Size
400 mm
Surface of rotor
Coated in black
Material of blades
Sheet steel, coated in black
Material of wall ring
Sheet steel, pre-galvanised and coated in
black plastic
Material of guard grille
Steel, phosphated and coated in black
plastic
Number of blades
5
Direction of air flow
"A"
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and
position as per EN 60034-5
Insulation class
"B"
Humidity class
F1-2
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Item no.: 12155-5-9970 · Revision: 76115 · Print-out: 2012-02-17 · Y. Uhlmann (VM-TDO) · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
1~
230
60
fa
CE
1700
240
1.06
6
400
75
-25
40
A
Static
No
1,00
Actual
Request
Request
2013
2015
31,9
25,3
29,3
42,6
36
40
0,2
2675
90
1390
Condensate discharge
Rotor-side
holes
Operation mode
S1
Motor bearing
Ball bearing
Leakage current
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
EN 60335-1; CE
to standard
Approval
CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Graphic rendition of products
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
8.8
mounting screws
You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.
Max. permissible
+ 80 °C
ambient motor temp.
(transp./ storage)
Min. permissible
- 40 °C
ambient motor temp.
(transp./storage)

Advertisement

Table of Contents
loading

Table of Contents