Lp/Propane Gas Conversion; Connect The Range To The Gas Supply - Frigidaire GLGS389FSA Installation Instructions Manual

30" gas slide-in range with sealed top burners
Hide thumbs Also See for GLGS389FSA:
Table of Contents

Advertisement

Available languages

Available languages

30" GAS SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
4.

Connect the range to the gas supply

Important:
Remove all packing material and
literature from range before connecting gas and
electrical supply.
To prevent leaks, put pipe joint sealant on all external
pipe threads.
Your regulator is in location shown below.
Do not
allow regulator to
rotate on pipe when
tightening fittings.
Figure 4
Connection to Pressure Regulator
The regulator is already installed on the appliance.
Do not make the connection too tight.
The regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible fire or
explosion.
GAS FLOW
Manual
Flare
Shutoff
Union
Valve
On
Nipple
Flexible
Off
Connector
All connections must be wrench-tightened
Figure 5
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
1. manual shutoff valve (not included)
2. 1/2" nipple (not included)
3. 1/2" flare union adapter (not included)
4. flexible connector (not included)
5. 1/2" flare union adapter (not included)
6. 1/2" nipple (not included)
7. pressure regulator (included)
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not
kinked.
The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in the
same room as the range and should be in a location that
allows ease of opening and closing. Do not block access
to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance.
(Models with Sealed Top Burners)
Once regulator is in place, open the shutoff valve in the
gas supply line. Wait a few minutes for gas to move
through the gas line.
Check for leaks. After connecting the range to the gas
supply, check the system for leaks with a manometer. If
a manometer is not available, turn on the gas supply and
use a liquid leak detector (or soap and water) at all
joints and connections to check for leaks.
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
Pressure
Flare
Regulator
Tighten all connections as necessary to prevent gas
Union
leakage in the range or supply line.
Isolate the range from the gas supply piping system
by closing its individual manual shutoff valve during any
Nipple
Access
pressure testing of the gas supply piping system at test
Cap
pressures equal to or less than 1/2 psig (3.5 kPa or 14"
water column).
5.
This appliance can be used with Natural gas or LP/Propane
gas. It is shipped from the factory for use with natural gas.
If you wish to convert your range for use with LP/Propane
gas, use the supplied fixed orifices located in a bag
containing the literature marked "FOR LP/PROPANE GAS
CONVERSION." Follow the instructions packaged with
the orifices for surface, oven and broil burners
conversion.
The conversion must be performed by a qualified service
technician in accordance with the manufacturer's
instructions and all local codes and requirements. Failure
to follow these instructions could result in serious injury
or property damage. The qualified agency performing
this work assumes responsibility for the conversion.
conversion can result in serious personal injury and
property damage.
5
t o
a p
p l i
a n
c e
Shutoff Valve -
Open position
Figure 6
Do not use a flame to check for leaks

LP/Propane Gas Conversion

Failure to make the appropriate
t o
g a
s s
u p
p l y
l i n
e

Advertisement

Table of Contents
loading

Table of Contents