Electrical Connection To The Range (U.s.a.); Three Conductor Wire Connection To Range - Frigidaire GLCS376CSA Installation Instructions Manual

30" dual fuel slide-in range
Hide thumbs Also See for GLCS376CSA:
Table of Contents

Advertisement

Available languages

Available languages

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
3. Electrical Connection to the Range
(U.S.A.)
This appliance is manufactured with the neutral terminal
connected to the frame.

Three Conductor Wire Connection to Range

(The 3-conductor cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply
cord (see Figure 4).
1. Remove the 3 screws at the lower end of the rear
wire cover, then bend the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection block (see Figure 3).
BEND REAR WIRE COVER HERE
FOR ACCESS TO ELECTRIC HOOK-UP
Figure 3
(Models with an Electric Oven and a Gas Cooktop)
2. Remove the 3 loose nuts (after you removed the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Connect the neutral white wire of the copper power
supply cord to the center silver-colored terminal of
the terminal block, and connect the other wires to
the outer terminals. Match wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal).
4. Replace the 3 nuts on the terminal block (see Figure
4).
5. Lower the terminal cover and replace the 3 screws.
Terminal
Block
Black
Wire
A User Supplied Strain-
relief Must Be Installed
at This Location.
4
Silver Colored Terminal
Cord
Mounting
Plate
Neutral
(White Wire)
Grounding
Strap
1 1/8" (2.9 cm) Dia.
Direct Connection
Hole. Punch Out
To 240 V
Knockout for 1 3/8"
Receptacle
(3.5 cm) Dia. Cord
Kit Hole.
Figure 4
Red
Wire

Advertisement

Table of Contents
loading