GAS COOKTOP INSTALLATION INSTRUCTIONS
Wall Outlet Location
Figure 4
Clamp Down Information
Once the cooktop is installed in the counter opening, you
must clamp the unit down as shown.
Figure 5
To clamp down, insert the bracket with the offset side of
the angle into the slots on each side of the unit. The
thumb screw should then be run through the bracket, up
against the bottom of the counter. Tighten until the unit
draws down.
(For Models with 4 Sealed Burners, Porcelain Enamel Cooktops)
Provide an Adequate Gas Supply
When shipped from the factory, this unit is designed to
operate on 4" (10 cm) water column (1.0 kPa) Natural
gas manifold pressure. A convertible pressure regulator
should be connected to the manifold and MUST be
connected in series with the gas supply line.
For proper operation, the maximum inlet pressure to
the regulator should be no more than 14" (35.6 cm) of
water column pressure (3.5 kPa).
The inlet pressure to the regulator must be at least
1"(2.6 cm) (.25 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" (10 cm)
water column (1.0 kPa) Natural gas manifold pressure,
the inlet pressure must be at least 5" (12.7 cm) water
column (1.25 kPa) Natural gas. For LP/Propane gas, the
regulator must be set for 10" (25.4 cm) water column
(2.5 kPa) manifold pressure, the inlet pressure must be
at least 11" water column (2.75 kPa).
The gas supply line to the range should be 1/2" (1.3 cm)
or 3/4" (1.9 cm) solid pipe.

LP/Propane Gas Conversion

This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
If you wish to convert your cooktop for use with LP/
Propane gas, order Kit No. 80-9000-10 from your local
retailer or from an authorized Service Agency (see
Warranty).
The conversion must be performed by a qualified service
technician in accordance with the manufacturer's
instructions and all local codes and requirements. Failure
to follow these instructions could result in serious injury
or property damage. The qualified agency performing
this work assumes responsibility for the conversion.
Failure
conversion can result in personal injury and property
damage.